24
Tr
oub
le
sho
ot
in
g
Fuse Replacement
If your WEBER CONNECT module is non-responsive even
after securing all electrical connections, it is possible
that the grill’s fuse has blown. The grill’s power supply
utilizes a cartridge fuse. This simple and inexpensive
part can be easily replaced with the following
instructions:
CAUTION: Only use the properly sized and rated
fuse when replacing. Failure to do so will void your
warranty. The correct fuse is:
1.6A
250V
5x20mm
Fast blow
1.
Make sure that the grill is completely cool, then
power off and unplug the grill from the power source
(A)
.
2.
The fuse is installed inside the fuse holder located
on the underside of the side table. Use a flathead
screwdriver to gently pry open the fuse holder and
remove the fuse
(B)
.
NOTE: WEBER recommends replacing the fuse if there is
suspicion of failure.
3.
Install a new fuse into the fuse holder and reinstall
the fuse holder into the power module
(C)
.
CAUTION: Make sure the fuse holder is fully
installed and closed before operating your grill.
4.
Plug in, power on the switch to allow the module to
run.
A
B
C