VENTILATION
WARNING: Ventilation holes must be provided in the
structure at the top and bottom to provide ventilation in the
event of a gas leak.
Ventilation holes can be located in a low visibility area and should be protected by
screening material to prevent rodents and insects from entering the structure. Air holes
will also help dry moisture.
Note: These drawings are only a reference.
• Cross ventilation must be incorporated in the supporting structure. We recommend a
minimum of 100 square inches (254 square cm) of venting per side.
• Vents should be on two sides of the structure.
• The drawings are for reference only.
• Position of the vents should be from the center, outward.
• Position the vents at both the bottom of the structure and at the top of the structure.
• The bottom vents should be as close to ground level as possible. Make sure the vent
area is not blocked by interior supports of the structure.
• We recommend vents with screens.
• Access doors to the structure are not considered vents.
• Clean the vents periodically.
VENTILATION
DANGER
Failure to follow recommended minimum venting
instructions can cause gas to collect in the structure in the
event of a gas leak. This may result in a fire or an explosion
which can cause serious bodily injury or death, and damage
to property.
◆
Summary of Contents for 660-LP
Page 11: ...WWW WEBER COM 11 1 2 460 660 ASSEMBLY ENSAMBLAJE ASSEMBLAGE ...
Page 13: ...WWW WEBER COM 13 5 6 ASSEMBLY ENSAMBLAJE ASSEMBLAGE ...
Page 14: ...14 7 8 ASSEMBLY ENSAMBLAJE ASSEMBLAGE ...
Page 15: ...WWW WEBER COM 15 9 10 ASSEMBLY ENSAMBLAJE ASSEMBLAGE ...
Page 18: ...18 15 16 ASSEMBLY ENSAMBLAJE ASSEMBLAGE ...
Page 23: ...WWW WEBER COM 23 25 26 ASSEMBLY ENSAMBLAJE ASSEMBLAGE ...
Page 25: ...WWW WEBER COM 25 1 2 28 ASSEMBLY ENSAMBLAJE ASSEMBLAGE ...
Page 34: ...34 MEMO ...
Page 67: ...WWW WEBER COM 67 MEMO ...