Weber 133873 Operator'S Manual Download Page 5

 
User’s Manual 

SOR 3 

 

 

 

 
Table of Contents 
 
Safety Notice for the User............................................................................................................................. 1

 

Table of Contents ......................................................................................................................................... 2

 

1.0 General ................................................................................................................................................... 3

 

2.0 Function .................................................................................................................................................. 3

 

2.3 Control Input........................................................................................................................................ 3

 

3.0 Construction............................................................................................................................................ 3

 

4.0 Technical Data........................................................................................................................................ 4

 

6.0 Conformity Declaration ........................................................................................................................... 4

 

7.0 Adjustment Possibilities .......................................................................................................................... 5

 

8.0 Operating Panel...................................................................................................................................... 5

 

8.1 Adjustment Procedure ........................................................................................................................ 5

 

9.0 Placing in Operation ............................................................................................................................... 6

 

9.1 Preliminary Measures ......................................................................................................................... 6

 

9.2 Working Frequency of the Built-in Magnets ........................................................................................ 6

 

9.3 Measurement of the Output Voltage and the Output Current ............................................................. 6

 

9.4 Restore Rated Value........................................................................................................................... 6

 

10.0 Adjustment............................................................................................................................................ 7

 

10.1 User Adjustment, Conveyor Capacity ............................................................................................... 7

 

10.2 Adaptation to the Conveyor .............................................................................................................. 7

 

11.0 Error Messages .................................................................................................................................... 8

 

12.0 Internal Connection............................................................................................................................... 8

 

13.0 Device Connections.............................................................................................................................. 9

 

14.0 Dimensional Diagram ........................................................................................................................... 9

 

 

Summary of Contents for 133873

Page 1: ...ACIEK SP KA JAWNA Jana Dlugosza 2 6 Street 51 162 Wroc aw Poland biuro rgbelektronika pl 48 71 325 15 05 www rgbautomatyka pl www rgbelektronika pl DATASHEET www rgbautomatyka pl www rgbelektronika pl...

Page 2: ...d with a wide variety of tools and having several testing stands at their disposal are a guarantee of the highest quality service OUR SERVICES ENCODERS SERVO DRIVERS LINEAR ENCODERS SERVO AMPLIFIERS C...

Page 3: ...Schraubautomaten GmbH Hans Urmiller Ring 56 D 82515 Wolfratshausen Tel 0049 8171 406 0 e Mail info weber online com Fax 0049 8171 406 111 www weber schraubautomaten de User s Manual SOR 3 Frequency c...

Page 4: ...r disassembly work and when fuses are changed or equipment modifications are undertaken Observe the applicable accident prevention and safety regulations for the respective application Before placing...

Page 5: ...5 8 0 Operating Panel 5 8 1 Adjustment Procedure 5 9 0 Placing in Operation 6 9 1 Preliminary Measures 6 9 2 Working Frequency of the Built in Magnets 6 9 3 Measurement of the Output Voltage and the O...

Page 6: ...even with supply voltage variations External release input 2 0 Function The operation of the device is achieved by means of a control panel on the front plate Keys and LED display All adjustments can...

Page 7: ...nal 100 m Standards 61000 6 2 EN 61000 6 4 Due to internal capacitors at the instant of switch on there is a load current impulse Especially when multiple devices are simultaneously switched on the ma...

Page 8: ...time 0 10 sec 0 1 sec 406 Enable function invert 0 1 En 0 406 Display software version number 001 8 0 Operating Panel 8 1 Adjustment Procedure When depressing the arrow keys a quick depression of the...

Page 9: ...then possibly be set by hand 9 2 Working Frequency of the Built in Magnets Because at small frequency adjustments the current flowing through the magnet may possibly increase by the first usage of the...

Page 10: ...e next menu point or scroll to the end of the menu until the rated value again appears on the display 6 The menu can also be directly exited and return to the normal operation is achieved by depressin...

Page 11: ...switching of the main power switch the device will be reset 12 0 Internal Connection Via the release input the device can be turned on or off with an external signal voltage of 24 V DC Release Supply...

Page 12: ...ielded output cable to the conveyor must be used 1 2 3 4 1 P E 2 3 1 P E 2 3 Main supply 110 230 V 50 60 Hz PE 3 4 1 1 L 2 N 3 nc 4 PE 1 A1 2 A2 3 Screen 4 PE 1 2 3 PE Output Feeder Enable input 3 GND...