Weber 133873 Operator'S Manual Download Page 4

 
User’s Manual 

SOR 3 

 

 

 

 

Safety Notice for the User 

 
This description contains the required information about the intended usage of the products described 
herein. It is intended for use by technically qualified personnel. 
 
Qualified personnel are those persons who, due to their training, experience and instruction, as well as 
their knowledge of the relevant standards, requirements, accident prevention regulations and operational 
conditions, are authorized by those responsible for the safety of the system to carry out their respective 
duties, and to recognize possible dangers and prevent them (Definition for experts according to IEC 364). 
 

Danger Notices 

 

 

Warning! 

Dangerous Voltage. 
Inattention can lead to death, serious injuries or damage to equipment. 
 

 

  Turn off the supply power before assembly or disassembly work and when fuses are changed or 

equipment modifications are undertaken. 

  Observe the applicable accident prevention and safety regulations for the respective application. 

  Before placing the equipment in operation, check whether the rated voltage of the device is in agree-

ment with the supply voltage. 

  Emergency OFF equipment must remain effective in all operating modes. Unlocking the emergency 

OFF equipment must not cause an uncontrolled startup of equipment. 

  The electrical connections must be covered! 

  Ground lead connections must be inspected after mounting to insure that they function per-

fectly! 

 

Usage According to the Regulations 
 

The devices described herein are electrical operational equipment for application in industrial systems. 
They are constructed for the regulation of oscillating conveyor equipment.  
 

The following notices serve to protect the personal safety of the operators and the safety of the described 
products as well as the devices connected to them.   

!

 

Summary of Contents for 133873

Page 1: ...ACIEK SP KA JAWNA Jana Dlugosza 2 6 Street 51 162 Wroc aw Poland biuro rgbelektronika pl 48 71 325 15 05 www rgbautomatyka pl www rgbelektronika pl DATASHEET www rgbautomatyka pl www rgbelektronika pl...

Page 2: ...d with a wide variety of tools and having several testing stands at their disposal are a guarantee of the highest quality service OUR SERVICES ENCODERS SERVO DRIVERS LINEAR ENCODERS SERVO AMPLIFIERS C...

Page 3: ...Schraubautomaten GmbH Hans Urmiller Ring 56 D 82515 Wolfratshausen Tel 0049 8171 406 0 e Mail info weber online com Fax 0049 8171 406 111 www weber schraubautomaten de User s Manual SOR 3 Frequency c...

Page 4: ...r disassembly work and when fuses are changed or equipment modifications are undertaken Observe the applicable accident prevention and safety regulations for the respective application Before placing...

Page 5: ...5 8 0 Operating Panel 5 8 1 Adjustment Procedure 5 9 0 Placing in Operation 6 9 1 Preliminary Measures 6 9 2 Working Frequency of the Built in Magnets 6 9 3 Measurement of the Output Voltage and the O...

Page 6: ...even with supply voltage variations External release input 2 0 Function The operation of the device is achieved by means of a control panel on the front plate Keys and LED display All adjustments can...

Page 7: ...nal 100 m Standards 61000 6 2 EN 61000 6 4 Due to internal capacitors at the instant of switch on there is a load current impulse Especially when multiple devices are simultaneously switched on the ma...

Page 8: ...time 0 10 sec 0 1 sec 406 Enable function invert 0 1 En 0 406 Display software version number 001 8 0 Operating Panel 8 1 Adjustment Procedure When depressing the arrow keys a quick depression of the...

Page 9: ...then possibly be set by hand 9 2 Working Frequency of the Built in Magnets Because at small frequency adjustments the current flowing through the magnet may possibly increase by the first usage of the...

Page 10: ...e next menu point or scroll to the end of the menu until the rated value again appears on the display 6 The menu can also be directly exited and return to the normal operation is achieved by depressin...

Page 11: ...switching of the main power switch the device will be reset 12 0 Internal Connection Via the release input the device can be turned on or off with an external signal voltage of 24 V DC Release Supply...

Page 12: ...ielded output cable to the conveyor must be used 1 2 3 4 1 P E 2 3 1 P E 2 3 Main supply 110 230 V 50 60 Hz PE 3 4 1 1 L 2 N 3 nc 4 PE 1 A1 2 A2 3 Screen 4 PE 1 2 3 PE Output Feeder Enable input 3 GND...

Reviews: