15
5
1
2
4
3
The start module
MS 15
1 Operational status indicator
(LED)
This indicator signals that the ignition of the machine is
switched on. It comes on as soon as the key switch (5) is set
to position “1”.
2 Oil pressure indicator (LED)
This indicator warns of insufficient oil pressure.
Shut down the machine immediately when this indicator comes
on.
3 Operating hours counter
This field shows the operating hours completed by the
machine.
The counter will show the remaining time until the next
scheduled maintenance for the first 10 seconds after the
ignition was switched on (key switch (5) in position “1”).
4 Charge level indicator (LED)
This indicator comes on if the charging current supply to the
starter battery is insufficient. While operation of the machine
can resume, the cause of the insufficient charging current
supply must be identified and rectified.
5 Key switch
The key switch is used to switch the power supply (ignition) to
the machine on or off. It also actuates the electric starter of the
engine.
Switch in position “1”
The ignition is switched on.
Switch in position “0”
The ignition is switched off.
Switch in position “2”
The electric starter is actuated.
Danger of material damage from running electric starter.
The ignition key must spring back from position “2” to position
“1”. Otherwise:
Shut down the machine immediately.
Figure 2
ATTENTION