First engine run and brake in
•
Prime the fuel system: Activate the fuel pump by turning on the key switch (not in start position).
• Connect
the
fl
ush system as described in section 4.2
•
Start engine. Do not accelerate. The engine may only be operated at idle speed for a maximum of 30
seconds without sea water
•
Ensure the water supply within 30 seconds
•
Check if the water out of the outer cooling loop is leaving the boat.
•
Check if the injected water is leaving the exhaust
•
Stop water supply
•
Check oil level as described on the hang tang on the oil tank
•
Check coolant level (1) of the inner cooling loop
1
ATTENTION
Coolant level below the MIN marking can cause damage
to the engine due to overheating.
Coolant level below the MAX marking should be avoided
to prevent environmental damage