Thermo 90
4 Technical Data
401
4
Technical Data
As long as no threshold values are given, the following
technical data are understood to include tolerances of
±10% usual for heaters at an ambient temperature of
+20° C and at nominal voltage and conditions.
Electrical Components:
Control unit, combustion air fan motor and dosing pump,
glow plug, control switch and timer are either of the 12 V
or 24 V type.
The components temperature limiter, temperature sensor,
and flame sensor are identical in the 12 V and 24 V units.
* not for Thermo 90-TRS
1)
Thermo 90-TRS 24 Volts only
2)
Thermo 90-S with control unit mounted on heater
Water Heater
Operation
Thermo 90 Fuel
Thermo 90 Diesel
Thermo 90-TRS
Type
BW 80
DW 80
Mark of conformity
~ S231
~ S232
Heater type
Water heater with
Ferro-Tec-Technology
Heat flow
max.
control range
2.0 – 7.6 kW
9.1 kW
1.8 – 7.6 kW
Type of fuel
Benzin
Diesel
Fuel consumption
max.
control range
0.25 – 1.0 l/h
1.1 l/h
0.19 – 0.9 l/h
Nominal voltage
12 Volt
12 or 24 Volt
1)
Operating voltage range
10 ... 15 Volt
10 ... 15 or 20 ... 30 Volt
Rated power consumption with
circulation pump (without vehicle blower)
max.
control range
37 W – 83 W
90 W
37 W – 83 W
Permitted ambient temperature:
Heater
– operation
– storage
Control unit
– operation
– storage
Dosing pump
– operation
– storage
–40 ... +110° C
–40 ... +130° C
–40 ... + 75° C
–40 ... + 85° C
–40 ... +20° C –40 ... +40° C
–40 ... + 85° C
Permitted overpressure (heat exchanger)
max.
2.0 bar
Heat exchanger capacity
0.15 l
Max. combustion air intake temperature
+40° C
Coolant circuit minimum capacity
6.00 l
Volume flow of circulation pump
against 0.15 bar
1650 l/h
CO
2
in exhaust
(perm. operating range)
max.
10 ... 12.0 Vol.-%
CO
2
-setting values at approx. +20° C and
geograph. height above SL
max.
0 m
500 m
1000 m
10 %
10.6 %
11.3 %
Dimensions heater
(Tolerance ± 3 mm)
Length
310 mm (355 mm)
2)
Width
133 mm
Height
220 mm
Weight
4.8 kg
Summary of Contents for Thermo 90
Page 9: ...1 Introduction 104 Page free for notes ...
Page 13: ...2 General Description Thermo 90 204 Page free for notes ...
Page 18: ...Thermo 90 3 Functional Description 305 Page free for notes ...
Page 20: ...4 Technical Data Thermo 90 402 Page free for notes ...
Page 26: ...6 Functional Tests Thermo 90 602 Page free for notes ...
Page 41: ...Thermo 90 8 Servicing 809 Page free for notes ...
Page 53: ...10 Packaging Storage and Shipping Thermo 90 1002 Page free for notes ...