background image

RS 2500 5 

5.1  Manual operation

If necessary, the RS 2500 can be operated manually. It depends on 
the situation which procedure for manual operation you must fol-
low.

CAUTION
Inadvertent movements of the manual operation 
tool

Risk of injury and/or damage of components.

 

X

Do not operate the control switch during manual 
operation.

 

X

Reset the control system after operating the 
RS 2500 manually. See chapter 5.2.

5.1.1  Manually moving the RS 2500 over a 

short range (less than 25 cm)

 

X

Gain access to the motor assembly.

 

X

Insert the tool for manual operation in the slot in the motor  
(See Fig. 05).

 

X

Turn the tool to close or open the RS 2500.

Fig. 05:  Manual operation tool

5.1.2  Manually moving the RS 2500 over 

more than 25 cm 

 

X

Gain access to the motor assembly.

If the RS 2500 is closed and locked, always first un-
lock the RS 2500 by means of the manual operation 
tool.

 

X

Insert the tool for manual operation in the slot in 
the motor (See Fig. 05).

 

X

Turn the tool to open the RS 2500 at least 10 cm 
to unlock the system.

 

X

Remove the tool for manual operation.

 

X

Disconnect the wiring harness (Fig. 06, 4) from the motor.

 

X

Remove the 3 bolts (3) and washers (2) from the motor (1).

 

X

Remove the motor.

Fig. 06: 

1

2

3

4

2

2

3

3

Motor removal

 

X

Push or pull the front beam of the RS 2500 to the desired (open 
or closed) position.

Fig. 07:  Manual closing or opening

5.2  Reset procedure

 

3

Make sure there is a minimum of 20 A available.

 

X

Press and hold the close button.

The RS 2500 closes as far as possible.

 

X

Release the close button.

 

X

Press and hold the close button.

After approx. 10 s the RS 2500 slides with small steps until it is 
completely closed
The motor produces a loud click sound.

 

X

Release the close button.

The system has been reset.

Fig. 08:  Control system reset

Reviews: