4
T
ECHNICAL
D
ATA
A
IR
T
OP
5000
4-2
423
151
>80
>45
Ø24
Ø25
148
>200
148
47.5
25
1
2
3
4
5
6
8
7
9
4.2
Dimensions
The mounting dimensions as well as the space required for the performance of servicing work are shown in figure 4-1.
1 Heating air inlet
2 Heating air outlet
3 Combustion air inlet
4 Exhaust gas outlet
5 Fuel inlet
6 Min. space required for heating air inlet (1.77 in.)
7 Min. space required for heating air outlet (3.14 in.)
8 Min. space required for removal of heater (7.89 in.)
9 Electrical cable outlet (optionally on right or left)
Dimensions expressed in millimeters
Fig. 4-1:
Dimensions - Air Top 5000
Fig. 4-2:
Fuel Pump - Air Top 5000
ATTENTION!
Webasto recommends installing gasoline-operated heaters so that the exhaust gas outlet points vertically down. Other
installation positions may cause increased wear to the burner.
ø 40 mm (1-9/16 in.)
137 mm (5-25/64 in.)
0°