Controller Models
8014, 8014ESR
Solo
Rain
®
Owner’s Manual
Page 1: ...8014 Series Battery Operated Valve Controller Controller Models 8014 8014ESR SoloRain Owner s Manual ...
Page 2: ......
Page 3: ... change without notice This controller is not intended for use by young children or the infirm without supervision Young children should be supervised to insure they do not play with this appliance If the supply cord is damaged it must be replaced by the manufacturer an authorized service agent or a similarly qualified person in order to avoid a hazard U S Patent No 6 314 340 TRADEMARKS Weathermat...
Page 4: ... 3 3 2 3 1 Set Water Days 3 3 2 3 2 Set Odd Even Days 3 3 2 3 3 Set Interval Days 3 3 3 Setting Additional Programs 3 3 4 Reviewing and Changing Your Watering Program 3 3 4 1 Reviewing Your Program 3 3 4 2 Changing Your Program 3 3 4 3 Clearing Watering Programs 4 3 4 3 1 Clear One Program 4 3 4 3 2 Clear All Programs 4 3 5 Running Your Controller 4 3 5 1 Run Your Scheduled Watering Program 4 3 5 ...
Page 5: ...Operating temperature range 32 to 140 F Dimensions 5 5 H x 3 25 W Made of ABS and nylon plastic construction Operating pressure 7 to 150 PSI Protective cover included 2 0 Installing the SoloRain Controller Replace the AC solenoid and bleed collar if one exists with the 8014 battery operated controller Do not over tighten The 8014 SoloRain fits Signature valve models 7900 1 series 9000 1 series 795...
Page 6: ...compatible 3 1 4 Changing the Time and Date Format The 8014 SoloRain controller can display time in either the 12 hour or 24 hour clock format When the 24 hour format is selected the date format will also change to Day Month To change the time and date format Rotate Select dial to the TIME or DATE position Press both the keys at the same time The PM indicator will disappear and the clock will chan...
Page 7: ...e water every 3 days waters every 10 days etc A value of 1 in an interval schedule means to water every day When using the interval option you have the flexibility to tell the controller what day to start the interval program on up to 30 days out Turn the SET dial to ODD EVEN position Use the keys to select O or E Turn the SET dial to INTERVAL Use the keys to select an interval from 01 30 PROGRAM ...
Page 8: ...time from 1 minute to 6 hours by using the keys at any time during the manual run To return to automatic operation turn the SET dial to RUN after the manual run has started The manual operation that you selected will finish and the timer will return to automatic operation as scheduled To stop manual watering rotate SET dial to the OFF position Note The 8014SR will override the sensor if activated ...
Page 9: ... completely and start over 5 0 Maintenance 5 1 Battery Replacement The long life 3 6 volt size AA Lithium battery is replaceable if necessary Remove the four screws under the control housing and gently open the unit Replace the battery Carefully replace the housing and install the four screws The battery is available as a service part 77482 from Weathermatic WARNING Damage to battery may cause fir...
Page 10: ...rs Signs of depletion Set the dial to Clear to clear the display Solid battery symbol appears Low battery Replace with a new battery RAIN DELAY symbol appears Rain delay is programmed Check rain delay progam ming RAIN DELAY appears 8014SR only Sensor has been tripped Adjust sensor settings as desired Rain Sensor symbol on Rain sensor is activated or if no rain sensor installed the jumper is missin...
Page 11: ...ly to the original user of the Weathermatic product If defect arises in a Weathermatic product or part within the warranty period you should contact your installing contractor Weathermatic retailer distributor or Weathermatic Weathermatic may at its option require that the product or part be returned to a Weathermatic service point or your retailer or distributor Weathermatic will determine whethe...