The AIS and GPS data should thus appear automatically on your plotter.
The cables are pre-assembled with connectors available and connected to the
main line using T-pieces (not included). The main cable, which is usually carried
out from stem to stern, must be completed at the two endings with a
terminator. One stub is the power supply that is connected through a fuse to
the 12V.
6.
Assembly and Installation
Attach the device to the 4 mounting holes with gully screws into the ship. Pay
attention to spacing disruptive devices (e.g. FM-transmitter) and avoid
excessive mechanical vibrations e.g. by the engine. Secure the wiring against
wobbling and rubbing (risk of a short circuit or malfunction).
Connect the N2Konnect with a NMEA2000 compatible cable via a T-piece with
the NMEA2000 bus of the ship. A 5-pin Micro Male connector is located at the
N2Konnect with external thread.
The NMEA0183 interface is connected via the white and green wire
:
Wiring:
White: NMEA 0183 IN+
Green: NMEA 0183 IN
-
IMPORTANT: The data rate of the NMEA0183 interface must be 38.4