Quick Instruction, Version 2.2
Page 26 of 43 pages
Weatherdock AG Sigmundstraße 180 90431 Nürnberg
Tel.:+49 911 37663835 www.weatherdock.de
Cable Colors and Cable Order
The easyTRX2 is connected to the PC by means of an USB plug. The USB
cable is enclosed in the box.
If you want to connect the easyTRX2 to a chart plotter please use the 6-
pole cable, marked with NMEA. You need two cables. The white one has
to be connected to the NMEA data input of the chart plotter, the green
one to the NMEA ground of the input. For the cable connection sche-
matics please look at following table:
Pos
Cable group
Qu
a
n
tit
y
o
f
ca
b
le
s
Fin
a
l
w
ir
e
co
lo
u
r
Functionality
P
in
a
t S
u
b
D
15
1
NMEA
6
Green
NMEA out 38400, (-)
9
2
NMEA
White
NMEA out 38400, (+)
1
3
NMEA
Pink
NMEA in 38400, (-)
10
4
NMEA
Grey
NMEA in 38400, (+)
2
5
NMEA
Brown
NMEA in 4800, (-)
11
6
NMEA
Yellow
NMEA in 4800, (+)
3
7
External switches
4
Green
SRM switch (-)
13
8
External switches
White
SRM switch (+)
5
9
External switches
Brown
Silent switch (-)
12
10
External switches
Yellow
Silent switch (+)
4
11
CPA & RESCUE ALARM
2
Brown
CPA Alarm (-)
14
12
CPA & RESCUE ALARM
White
CPA Alarm (+)
6
13
Power
2
Black
Power 9.6-31.2 VDC (-)
./.
14
Power
Red
Power 9.6-31.2 VDC (+)
./.