background image

3

WE-EF Eco Step Dim® Basic

Class I

Phase (L1) to 1, Control Phase (L2) to 2, 

Neutral (N) to 3 and Earthing 

Class II

Phase (L1) to 1, Control Phase (L2) to 2, 

Neutral (N) to 3 

1-10V / DALI / WE-EF Eco Step Dim® Dynamic

Class I

Phase (L1) to 1, Neutral (N) to N, Control 

Phase (+) to 2, Control Phase (–) to 3 and 

Earthing 

Class II

Phase (L1) to 1, Neutral (N) to 3, Control

Phase (+) to 2, Control Phase (–) to 4

Compare the local voltage and frequency with date 

mentioned on the label of the luminaire.

Screw the gland nut together, tightening to a torque 

of 10 Nm (

fig. 5

).

3) Pull the connecting cable through the pole. Put the

luminaire on top of the pole and tighten the fixing

screws 

B

, tightening to a torque of 10 Nm.

Maintenance

Apart from cleaning the product’s exterior surfaces, no 

special maintenance work is required. Do not use high-

pressure cleaners.

WE-EF Eco Step Dim® Basic

SKI

Phase (L1) an 1, Steuerphase (L2) an 2, 

Neutralleiter (N) an 3 und Schutzleiter an 

SKII

Phase (L1) an 1, Steuerphase (L2) an 2, 

Neutralleiter (N) an 3 

1-10V / DALI / WE-EF Eco Step Dim® Dynamic

SKI

Phase (L1) an 1, Neutralleiter (N) an N, 

Steuerphase (+) an 2, Steuerphase (–) an 3 

und Schutzleiter an 

SKII

Phase (L1) an 1, Neutralleiter (N) an 3, 

Steuerphase (+) an 2, Steuerphase (–) an 4

Vergleichen Sie die örtliche Spannung und Frequenz

mit den Daten auf dem Leistungsschild.

Verschrauben Sie die Überwurfmutter mit einem

Anzugs drehmoment von 10 Nm (

Abb. 5

).

3) Das Anschlusskabel durch den Mast ziehen. Die

Leuchte auf den Mast aufsetzen und die Befestigungs -

schrauben 

B

der Leuchte mit einem Anziehmoment von

10 Nm anziehen.

Wartung

Abgesehen von der äußerlichen Reinigung des Produkts ist

keine besondere Wartung erforderlich. Keine

Hochdruckreiniger verwenden.