WE-EF RMC320 LED Installation And Maintenance Instructions Download Page 4

3)  Pull the connecting cable through the pole. Put 

the luminaire on top of the pole 

D

 and tighten 

the fixing screws 

E

, tightening to a torque of 

5 Nm (44.3 in-lb).

Installation Procedure Pole Installation

Luminaire prewired, do not open!

 
1)  Switch off the mains electrical supply. 

2)  Cut cable to the corresponding height of the 

pole and connect cable to the connector 

B

 

(

fig. 1-6

).

0-10V

Phase (L1) to 1, Neutral (N) to N, Control Phase 
(+) to 2, Control Phase (–) to 3 and Earthing 

For protection class II, the earthing is omitted.

  Screw the gland nut together, tightening to a 

torque of 5 Nm (44.3 in-lb) (

fig. 5)

.

WE-EF Eco Step Dim® Advanced / ON-OFF

R

J
P

O

Individual wiring

Through wiring

1-10V / DALI

R

J

O

P

Individual wiring

Through wiring

0-10 V

For ON/OFF

Reviews: