For larger cable diameters of 0.354 – 0.472 in
the enclosed cable entries must be used.
Then tighten the pressure screw firmly. To fix
the mounting flange
J
, insert screws
L
, and
tighten firmly.
5) Connect mains supply cable
N
to respective
terminals
P
in terminal connector (N = Neutral,
L= Phase, = Earthing).
6) Position luminaire/wall bracket
Q
by attaching
to mounting flange
J
and secure in position by
firmly tightening screws
K
.
Procedure wall mounting installation
Luminaire prewired, do not open!
1) Switch off the mains electrical supply.
2) Remove mounting flange
J
by releasing
screws
K
.
3) Determine positions for fixing screws
L
. Ensure
the arrow mark
R
on the flange
J
label aims
upwards. Drill relevant holes and insert heavy
duty wall plugs
M
.
ATTENTION:
Make sure not to damage any
electric cable, water pipe or other devices while
drilling holes.
4) Feed mains supply cable
N
(and the second
cable for through wiring, if required) through
packing ring
O
, while setting and fixing moun-
ting flange
J
in position. The pre-installed
packing ring
O
is suitable for cable diameters
0.276 – 0.374 in.
E
B
A
D
H 80 mm
ø 76 mm
Installation to a pole
J
N
M
O
L
K
Q
Installation to a wall bracket
fig. 1
fig. 4
fig. 7
fig. 2
fig. 5
fig. 3
fig. 6
A
B
5 Nm
(44.3 in-lb)
PE ~ 180°
~ 2.5 in