WE-EF RMC320 LED Installation And Maintenance Instructions Download Page 3

  For larger cable diameters of 0.354 – 0.472 in 

the enclosed cable entries must be used.

  Then tighten the pressure screw firmly. To fix 

the mounting flange 

J

, insert screws 

L

, and 

tighten firmly.

5)  Connect mains supply cable 

N

 to respective 

terminals 

P

 in terminal connector (N = Neutral, 

L= Phase,   = Earthing).

6)  Position luminaire/wall bracket 

Q

 by attaching 

to mounting flange 

J

 and secure in position by 

firmly tightening screws 

K

.

Procedure wall mounting installation

Luminaire prewired, do not open!

1)  Switch off the mains electrical supply. 

2)  Remove mounting flange 

J

 by releasing 

 screws 

K

.

3)  Determine positions for fixing screws 

L

. Ensure 

the arrow mark 

R

 on the flange 

J

 label aims 

upwards. Drill relevant holes and insert heavy 
duty wall plugs 

M

ATTENTION:

 Make sure not to damage any 

electric cable, water pipe or other devices while 
drilling holes.

4)  Feed mains supply cable 

N

 (and the second 

cable for through wiring, if required) through 
packing ring 

O

, while setting and fixing moun-

ting flange 

J

 in position. The pre-installed 

packing ring 

O

 is suitable for cable diameters 

0.276 – 0.374 in.

E

B

A

D

H 80 mm

ø 76 mm

Installation to a pole

J

N

M

O

L

K

Q

Installation to a wall bracket

fig. 1 

fig. 4 

fig. 7 

fig. 2 

fig. 5 

fig. 3 

fig. 6 

A

B

5 Nm 

(44.3 in-lb)

PE ~ 180°

~ 2.5 in

Reviews: