Installation
The product must be installed and maintained by a
VXLWDEO\TXDOLƂHGSURIHVVLRQDOLQFRPSOLDQFHZLWKODWHVW
building/construction and/or electrical regulations and
relevant legislation.
Warning:
Switch off mains electrical supply prior to
installing and connecting the luminaire.
Notice:
,IWKHOXPLQDLUHLVPRGLƂHGE\DQ\ERG\RWKHU
than the original manufacturer, then the warranty will
no longer be valid and shall become the full respon-
sibility of the modifying person/organisation. Claims
based on defects attributable to improper installation
and/or application, and the consequences thereof, are
excluded.
Installation Methods
For concrete or brick walls with recess provided by civil
contractor:
a) BQR installation blockout (Fig. I).
b) Cavity (Fig. II).
Installation Procedure
1) Switch off mains electrical supply.
2) Remove cover
A
by loosening screws
B
.
3) Check that rating shown on luminaire label conforms
with mains electrical supply.
4) Check that the recess provided can accommodate
luminaire housing.
a) For installation with BQR installation blockout:
Attention:
Nylon plugs
C
must remain in position
to provide sealing.
b) For cavity installation: Determine positions for
Ƃ[LQJVFUHZV
D
. Drill relevant holes
E
and insert
nylon plugs
F
.
Warning
: Ensure not to damage any electrical cable,
water pipe or other items drilling holes.
5) Feed mains supply cable
G
(and second cable
H
for
through wiring, if required) through cable gland
I
at bottom of housing, while setting and securing
luminaire in position (Fig. III).
6) Connect mains supply cable
G
leads to respective
terminals in terminal connector
K
:
D212))/ 3KDVH1 1HXWUDO (DUWKLQJ
E9'$/,/ 3KDVH1 1HXWUDO
(DUWKLQJ'$'$ '$/,FRQWUROOLQH
't' 9FRQWUROOLQH
5HSRVLWLRQFRYHU
A
and retighten screws
B
.
Fig. I
Fig. II