background image

4

Zubehör / Installation Accessories

Passende Mast- und Wandausleger und Mastschellen siehe WE-EF Katalog.

Suitable pole- and wall brackets and clamps please refer to the actual WE-EF catalogue.

Ausleger/
Brackets 
Serie KI

Lamp Replacements and Maintenance

Do not open luminaire while in operation or while mains

supply is switched on!

1) Switch off the mains electrical supply. 

2) Loosen the screws 

B

and open frame 

A

Clean the lens with a suitable mild detergent. 

Check gaskets for damage and replace if necessary.

3) Exchange lamp (Lamp performance and lamp base

have to correspond with the data mentioned on the

label of the luminaire).

4) Close frame 

A

and firmly tighten screws 

B

.

Protect our enviroment: Discard used lamps in compliance

with the most recent environmental legislation.

Lampenwechsel und Wartung

Leuchtengehäuse nicht während des Betriebes öffnen!

1) Spannungsfreiheit der Anschlussleitung her stellen. 

2) Rahmen 

A

durch Lösen der Schrauben 

B

öffnen.

Abdeckung mit geeignetem Reinigungsmittel säubern.

Dichtung auf Funktionsfähigkeit überprüfen und ggf.

austauschen.

3) Lampe wechseln (Lampentyp, -leistung und Sockel

müssen mit den Angaben auf dem Leuchtenleistungs -

schild übereinstimmen).

4) Rahmen 

A

schließen und Schrauben 

B

fest anziehen.

Für die Entsorgung der Lampe sind die zur Zeit gültigen