background image

Installation

The product must be installed and maintained by a 

VXLWDEO\TXDOLƂHGSURIHVVLRQDOLQFRPSOLDQFHZLWKODWHVW

 

building/construction and/or electrical regulations and 

relevant legislation.

Warning:

 Switch off 

and isolate the 

mains electrical 

supply prior to installing and connecting the luminaire.

Notice:

,IWKHOXPLQDLUHLVPRGLƂHGE\DQ\ERG\RWKHU

 

than the original manufacturer, then the warranty will 

no longer be valid and shall become the full respon-

sibility of the modifying person/organisation. Claims 

based on defects attributable to improper installation 

and/or application, and the consequences thereof, are 

excluded.

If the supplied cable of the KTX luminaire is damaged, 
it must be replaced by WE-EF or a WE-EF authorized 
agent.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

head retention screw

 

X

.

secure by tightening screw

s

 

D

 

(not KTX) and the

 

Return head of luminaire

 

B

 

to bollard post

 

C

 

and

 

8)

= 1-10V control line).

Earthing, DA/DA = DALI control line, D-/D+

 

1-10V/DALI (L = Phase, N = Neutral,      =

 

b)

Earthing)

ON/OFF (L = Phase, N = Neutral,     =

 

a)

the terminal

 

block:

Wiring is as

 

follows and should match the labels on

 

7)

junction box

 

J

 

(not supplied)

 

as per Fig. 3

.

and must be connected via a compliant

 

IP67

 

clamp

 

H

.

 

Note :

 

The KTX

 

does not have t

he

 

gear tray

 

the underside of the head

 

B, and is secured by the

 

supply terminal block located on the gear tray

 

G

 

on

 

As per Fig. 2 Connect luminaire cable

 

I

 

to mains

 

6)

the head retention screw

 

X

 

is positioned.

on KTX)

.  Note that the rear of the bollard is where

 

the base with retention bolts

 

D

 

(base is integrated

 

and tightening bolts

 

G

 

and the post

 

C

 

is attached to

 

Set cast base

 

F

 

in position and secure by inserting

 

5)

(see previous page)

.

rotating it anti-clockwise until it can be lifted up

after loosening screw

 

X

 

with

 

a

 

Torx T-20 tool and

 

Remove head of luminaire

 

B

 

from bollard post

 

C

 

4)

mains cable length are provided.

(QVXUHWKDWDVROLGIRXQGDWLRQDVZHOODVVXIƂFLHQW

 

A suitable recess to be provided for planted root

 

A

.

 

3)

conforms

 

with mains electrical supply.

Check that

 

rating

 

shown

 

on

 

luminaire

 

label

2)

Switch off

 

and isolate the

 

mains electrical supply.

1)

maximum stability.

incorporate the optional planted root to ensure

 

to an even surface, however it is recommended to

 

The luminaire is suitable for installation directly on

Installation Procedure

)

 

DC (+ = Positive, - = Negative) 

c

6

Summary of Contents for KTY234

Page 1: ...activated prior to luminaire installation Also disconnect luminaires before operating high power devices such as for example electrical arc welders Do not open during installation This product is factory sealed Refer to the instructions contained in this document for details Installation tools Mounting hardware used on this product includes fasteners with hexalobular socket heads ISO 10664 Install...

Page 2: ......

Page 3: ...1000 ø 180 600 ø 180 H kg 600 7 8 1000 8 9 IP66 Class I Class II III available on request ta 25 C H 600 mm ZFY230 Bollard H 1000 mm ZFY230 for ZFY230 for ZFY230 Weight ESV4 for ZFY230 Planted root Galvanised steel Accessories ...

Page 4: ... 0461 3 2 Bollard 270 ø 180 KTX234 H 270 mm for KTX234 270 4 5 Weight IP66 Class I Class II III available on request ta 25 C H 600 mm KTY234 H 1000 mm KTY234 for KTY234 for KTY234 ESV4 for KTY234 Planted root Galvanised steel Accessories ...

Page 5: ...59 1000 18 kg Accessories Planted root Galvanised steel ESV4 for CFY259 300 0464 4 4 Bollard CFY259 H 685 mm CFY259 H 1085 mm CFY259 H600 6 LED CFY259 H1000 2x6 LED WARNING HEAVY ITEMS Ensure correct handling techniques are used IP66 Class I Class II III available on request ta 25 C ...

Page 6: ... To remove the head of the luminaire during maintenance loosen screw X with a Torx T 20 tool and Do not use high pressure cleaners Apart from cleaning the product s exterior surfaces no special maintenance work is required Maintenance LED Light Source ...

Page 7: ...ove head To insert head u j k l v into the body and v rotate clockwise When seated wsecure the head by tightening screw X bollard body To re attach the head align it to the bollard post as shown below u drop the head jRelease the grub screw X and k twist the head counter clockwise then l lift the head off the Head Removal bollard with the WE EF logo at the front of the bollard For ZFY230 CFY250 Th...

Page 8: ...nd should match the labels on 7 junction box J not supplied as per Fig 3 and must be connected via a compliant IP67 clamp H Note The KTX does not have the gear tray the underside of the head B and is secured by the supply terminal block located on the gear tray G on As per Fig 2 Connect luminaire cable I to mains 6 the head retention screw X is positioned on KTX Note that the rear of the bollard i...

Page 9: ...Torque Screw Torque M4 max 2 0 Nm M5 max 4 0 Nm M6 max 6 0 Nm M8 max 15 0 Nm M16 max 100 0 Nm C B D F E A Fig 1 J H G Fig 2 Fig 3 I 7 ...

Page 10: ......

Page 11: ......

Page 12: ...EF LIGHTING United Kingdom Tel 44 844 880 5346 Fax 44 844 880 5347 info uk we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 LQIR DVLDSDFLƂF ZH HI FRP WE EF LIGHTING Australia Tel 61 3 8587 0444 Fax 61 3 8587 0499 info australia we ef com WE EF LIGHTING United States of America Tel 1 724 742 0030 Fax 1 724 742 0035 info usa we ef com INSTALLER HOTLINE 61 458 933 399 7am 7pm AES...

Page 13: ...WE EF LIGHTING Installation and Maintenance Instructions for Planted Root ESV4 ...

Page 14: ...This page intentionally left blank 1 ...

Page 15: ... 6 ESV4 300 0461 ESV4 300 0464 Ø150 Ø220 200 200 400 400 100 50 100 50 Suitability 1 FLC230 240 2 KTX Y234 AP 3 ZFY230 AP 4 G_Y224 AP Suitability 1 CFY259 2 ZFY250 AP 3 G_Y234 AP 4 C_Y150 5 RRX324 6 XR_324 AP If in doubt please contact you WE EF authorised agent for the suitability of ESV plant root type with nominated luminaire 3 9 kg 6 1 kg ...

Page 16: ...lease note the ESV must be orientated correctly for different products In both instances the conduit entry can be rotated to match cable routing When the ESV is being installed for the following products KTY234 KTX234 ZFY230 CFY259 please orientate the bolt pattern as shown base plate is 45 to the pathway For this installation use the 40mm long M8 bolts supplied 3 For all other product please orie...

Page 17: ...top and bottom The bolts are inserted to protect the threads off the plate and need to be removed for fitting installation after setting the ESV 4 6 Pour concrete to desired level depending on requirement of soil paver or concrete Ensure that for any installation the mounting plate must be flush or higher than the surrounding surface level 4 After the concrete has cured for the specified time remo...

Page 18: ...5 This page intentionally left blank ...

Page 19: ...6 This page intentionally left blank ...

Page 20: ... usa we ef com WE EF LEUCHTEN Germany Tel 49 5194 9090 Fax 49 5194 909299 info germany we ef com WE EF LUMIERE France Tel 33 4 74 99 14 44 Fax 33 4 74 99 1440 info france we ef com WE EF HELVETICA Switzerland Tel 41 22 752 4994 Fax 41 22 752 4974 info switzerland we ef com WE EF LIGHTING UnitedKingdom Tel 44 844 8805346 Fax 44 844 8805347 info uk we ef com www we ef com WE EF2021 Technical specifi...

Reviews: