background image

1

IP55*, IP66**, IK10, Class I, ta = 40°C

Bollard

XRY324**

XRY334**

RRY324**

RRY334**

GRY224**

GRY234**

RRZ324*

RRZ334*

XRZ324*

XRZ334*

Summary of Contents for GRY224 LED

Page 1: ...e protection of a luminaire installation against lightning and electrical surges it is essential to cover mains supply and data input lines at the distribution board level by using respective primary Type 1 and secondary Type 2 surge arrestors in compliance with EN61643 11 IEC61643 1 Warning Ensure that all required surge protection measures are in place and activated prior to luminaire installati...

Page 2: ...1 IP55 IP66 IK10 Class I ta 40 C Bollard XRY324 XRY334 RRY324 RRY334 GRY224 GRY234 RRZ324 RRZ334 XRZ324 XRZ334 ...

Page 3: ...ns supply is switched on Product Dimensions A B C D GRY224 ø 160 700 ø 130 ø 160 GRY234 ø 250 1000 ø 202 ø 230 XRY324 ø 180 700 ø 202 ø 230 XRY334 ø 270 1000 ø 286 ø 320 XRZ324 ø 180 900 ø 202 ø 230 XRZ334 ø 270 1100 ø 286 ø 320 RRY324 ø 205 900 ø 202 ø 230 RRY334 ø 320 1000 ø 286 ø 320 RRZ324 ø 205 900 ø 202 ø 230 RRZ334 ø 320 1100 ø 286 ø 320 ESV4 Accessories Planted root Galvanised steel kg ESV...

Page 4: ...witch off mains electrical supply prior to installing and connecting the luminaire Notice If the luminaire is modiƂed by anybody other than the original manufacturer then the warranty will no longer be valid and shall become the full respon sibility of the modifying person organisation Claims based on defects attributable to improper installation and or application and the consequences thereof are...

Page 5: ...k screws D 2 Check that rating shown on luminaire label conforms with mains electrical supply example XRZ334 220 240V 50Hz 1 10v 114 9632 SOE XXXXXXX LED 4000K 12W item no XXX 05 17 IP55 3 A suitable recess to be provided for planted root A Ensure that a solid foundation as well as sufƂcient mains cable length are provided Note Planted root installation instruction is available at the end of this ...

Page 6: ...V DALI 5 Connect luminaire cable E to mains supply cable F in watertight terminal connector G not supplied by WE EF 8 Reposition cover B and secure by tightening screws D 6 Place watertight terminal connector G and excess cable inside post H 7 Set luminaire in position and secure by inserting and tightening bolts I ...

Page 7: ...nd Tel 41 22 752 49 94 Fax 41 22 752 49 74 info switzerland we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 info asiapaciƂc we ef com WE EF LIGHTING Australia Tel 61 3 8587 0444 Fax 61 3 8587 0499 info australia we ef com WE EF LIGHTING United States of America Tel 1 724 742 0030 Fax 1 724 742 0035 info usa we ef com TO9233W0219 WE EF 2019 Technical speciƂcations are subject ...

Page 8: ...WE EF LEUCHTEN Installation and Maintenance Instructions Planted Root ESV4 ESV2 ESV6 ...

Page 9: ...4 300 0586 ESV4 300 0464 ESV4 300 0459 Suitability 1 KTX234 2 KTY234 3 ZFY230 4 GRY224 5 Short post Suitability 1 XRY334 2 XRZ334 3 RRY334 4 RRZ334 Suitability 1 CFY259 2 GRY234 3 RRY324 4 RRZ324 5 XRY324 6 XRZ324 Suitability 1 QSI254 ...

Page 10: ...3 Planted Root ESV2 300 9115 ESV6 300 0824 ESV6 300 0457 Suitability 1 PSY414 424 Suitability 1 AML C 2 FLA461 Suitability 1 LTM440 2 LTM444 3 AMW C 4 AMF C 5 AMF S 6 AML C 240 200 600 ...

Page 11: ...late is parallel to the pathway For this installation use 30 mm long M12 bolts supplied 2 Please note ESV4 and ESV6 must be orientated correctly for different products In both instances conduit entry can be rotated to match cable routing When the ESV is being installed for following products KTY234 KTX234 ZFY230 CFY259 FLA461 please orientate the planted root as shown base plate is at an angle of ...

Page 12: ...ts supplie 7 Place the ESV in the form work for concrete pad ensuring orientation position and levels are correct Ensure all openings on ESV are blanked off including mounting plate hole 8 Fit the nominated bolts through mounting ƃDQJH QVXUH VHYHUDO WKUHDGV IHHG WKURXJK the plate and tape off top and bottom Bolts are inserted to protect threads off plate and need to EH UHPRYHG IRU ƂWWLQJ LQVWDOODW...

Page 13: ...paver or concrete Ensure WKDW IRU DQ LQVWDOODWLRQ PRXQWLQJ ƃDQJH PXVW EH ƃXVK RU KLJKHU WKDQ VXUURXQGLQJ VXUIDFH OHYHO IWHU FRQFUHWH KDV FXUHG IRU VSHFLƂHG WLPH UHPRYH EODQNLQJ DQG EROWV QVWDOO ƂWWLQJ as per luminaire instructions onto mounting ƃDQJH Concrete Paver Soil ...

Page 14: ...nd Tel 41 22 752 49 94 Fax 41 22 752 49 74 info switzerland we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 LQIR DVLDSDFLƂF ZH HI FRP WE EF LIGHTING Australia Tel 61 3 8587 0444 Fax 61 3 8587 0499 info australia we ef com WE EF LIGHTING United States of America Tel 1 724 742 0030 Fax 1 724 742 0035 info usa we ef com TO9257W0420 WE EF 2020 7HFKQLFDO VSHFLƂFDWLRQV DUH subject ...