3
Installation
The product must be installed and maintained by a
suitably quali
Ƃ
ed professional in compliance with latest
building/construction and/or electrical regulations and
relevant legislation.
Warning:
Switch off mains electrical supply prior to
installing and connecting the luminaire.
Notice:
If the luminaire is modi
Ƃ
ed by anybody other
than the original manufacturer, then the warranty will
no longer be valid and shall become the full respon-
sibility of the modifying person/organisation. Claims
based on defects attributable to improper installation
and/or application, and the consequences thereof, are
excluded.
Installation Procedure
1) Switch off mains electrical supply.
2) Remove mounting
ƃ
ange
A
by loosening screws
B
.
Detach terminal connector
C
.
3) Determine position for
Ƃ
xing screws
D
(diameter
ST4.8, type ISO 7049 or similar). Drill relevant holes
E
and insert nylon plugs
F
.
Warning
: Ensure not to damage any electrical
cable, water pipe or other items drilling holes.
4) Feed mains supply cable
G
(and second cable
H
for
through wiring, if required) through cable gland
I
,
while setting mounting
ƃ
ange
A
in position. The
pre-installed cable gland
I
is suitable for cable
diameters 1 to 9 mm.
) To
Ƃ
x mounting
ƃ
ange
A
, pierce through nylon
plugs
J
by inserting and tightening screws
D
.
Attention
: The nylon plugs
J
must remain in posi-
tion to provide sealing.
6) Check that rating shown on luminaire label conforms
with mains electrical supply.
7) Connect mains supply cable
G
leads to respective
terminals on
ƃ
ange plate
K
(N = Neutral, L= Phase,
= Earthing).
For 1-10 V analogue dimming interface, connect
mains supply cable
G
leads to respective terminals
in terminal connector
K
(N = Neutral, L = Phase,
= Earthing) and (D+, D– = external 1-10 V dim-
ming device). See Fig. I.
8) Ensure that all surfaces are clean and dry. Position
luminaire over mounting
ƃ
ange
A
and attach termi-
nal connector
C
. Tighten screws
B
evenly.
9) Loosen screws
M
and
N
slightly. Aim luminaire in
desired direction, tighten screws
M
and
N
. Tighten
set screw
O
.