4
Wiring Diagram Cable Connector
WE-EF Eco Step Dim® Advanced and non dimmable
luminaires
Class I
Phase (L1) to 1, Neutral (N) to 3 and
Earthing
Class II
Phase (L1) to 1, Neutral (N )to 3
WE-EF Eco Step Dim® Basic
Class I
Phase (L1) to 1, Control Phase (L2) to 2,
Neutral (N) to 3 and Earthing
Class II
Phase (L1) to 1, Control Phase (L2) to 2,
Neutral (N) to 3
1-10V / DALI / WE-EF Eco Step Dim® Dynamic
Class I
Phase (L1) to 1, Neutral (N) to N, Control
Phase (+) to 2, Control Phase (–) to 3 and
Earthing
Class II
Phase (L1) to 1, Neutral (N) to 3, Control
Phase (+) to 2, Control Phase (–) to 4
Compare the local voltage and frequency with date
mentioned on the label of the luminaire.
Screw the gland nut together, tightening to a torque
of 5 Nm (
fig. 8
).
Schéma de raccordement
WE-EF Eco Step Dim® Advanced et luminaires non
programmables
Classe I
Phase (L1) sur 1, Neutre (N) sur 3
et terre
Classe II
Phase (L1) to 1, Neutre (N) sur 3 et terre
fonctionnelle
WE-EF Eco Step Dim® Basic
Classe I
Phase (L1) sur 1, Fil pilote (L2) sur 2,
Neutre (N) sur 3 et terre
Classe II
Phase (L1) sur 1, Fil pilote (L2) sur 2,
Neutre (N) sur 3 et terre fonctionnelle
1-10V / DALI / WE-EF Eco Step Dim® Dynamic
Classe I
Phase (L1) sur 1, Neutre (N) sur N,
Fils DALI sur DALI et terre
Classe II
Phase (L1) sur 1, Neutre (N) sur N,
fils DALI sur DALI et terre fonctionnelle
Vérifiez le bon voltage / fréquence avec celui de l’appareil.
Serrez le presse étoupe avec un couple de 5 Nm (
fig. 8
).
Summary of Contents for CFS500 Series
Page 8: ...7 fig 8 fig 9 fig 10 fig 7...