Mounting of the contact sensor on the steam line 

 

The temperature sensor type NTC 20 KΩ, is a contact sensor for mounting at steam-carrying tubes. The sensor measures the temperature at 

the pipe wall of the steam pipe.  

 

Article no.: 23721 
 

Scope of delivery:  

Temperature sensor NTC 20 kOhm 

incl. tensioning chain with spring 

 

 

 

 

 
 

Mounting: 

 

 

 

 

Take the coil spring with the small chain, placing them on the steam pipe and hook the chain with a slight tension on the coil spring. 

Check if the chain is securely hooked on the coil spring.  

 

Now pull the coil spring from the steam pipe up and push the head of the temperature sensor between the steam pipe and the coil 
spring, so that the coil spring is located in the recess of the sensor head (see picture). Look out for a tight fit of the sensor head. 

 

Then you adjust the desired dosing value at the rotary knob for the dosage. The dosing pump delivers per second running time approximately 

1 ml fragrance. The green LED indicates the unit is read to operate. The yellow LED temperature indicates reaching the set temperature of the 

steam line. 

 

Because the dosage of the fragrance is coupled via the contact sensor to the steam generator it will only dosed when the steam pipe is hot 

and at the same time the steam generator produces steam. 

 
 

9. 

Maintenance 

 

The DUFTDOS dosing pumps are practically maintenance-low and giving long life if the following points are considered: 
 

-

 

Unsuitable fragrances are not used 

-

 

check the pump head every time you change the canister 

-

 

at least change the pump hose twice a year, or as needed 

 

If the unit is taken out of service remove the dosing hose from the pump (see under setion 6.1) to prevent long term deformation of the hose.  

 

 

Attention!  

 

Risk of scalding at the hot steam lines! 

Temperature sensor with tensioning 
chain and spring 

Summary of Contents for Duftdos UNPL

Page 1: ...bols 2 2 Saftey 3 2 1 Technical safety advice 3 2 2 Use in accordance with regulations 4 3 Delivery 4 4 Function 4 5 Technical Data 5 6 Fragrance pump 5 6 1 Change the hose set 6 6 2 Sparepartlist per...

Page 2: ...essible at all times 1 4 Further informations For further information please contact your dealer or company WDT Werner Dosiertechnik GmbH Co KG 1 5 Used symbols Danger Warning of Danger Failure to obs...

Page 3: ...y After any repair work have qualified personnel check the safe operation of the unit Use original spare parts only Additional national safety regulations also fully apply to the operation of this uni...

Page 4: ...After you press the push button the dosing is activated for 0 5 seconds till 5 seconds adjustable and aroma is injected into the steam pipe Afterwards the dosing is locked for an adjustable 1 20 minu...

Page 5: ...6 Fragrance pump A peristaltic dosing pump is used for dosing which safely promotes also smallest quantities Even when Air or gas bubbles are trapped in the suction line Rotating rolls press the dosi...

Page 6: ...t persitaltic pump frangrance The peristaltic pump article no Transparent pump cover Sa 14259 Safety disc for roller Sa blue 13633 Hose holder Sa for fragrance with Viton hose 13358 Hose set Sa 2 dosi...

Page 7: ...ommissioning Dosing The dosing unit has to be mounted in an easily accessible place on the wall about 1m above the floor The fragrance canister is placed under the unit The suction hose is inserted in...

Page 8: ...sensor head Then you adjust the desired dosing value at the rotary knob for the dosage The dosing pump delivers per second running time approximately 1 ml fragrance The green LED indicates the unit i...

Page 9: ...suring points is 730 ohms If the switch on temperature should be changed so you can do these when you turn the adjustment screw at the potentiometer If you turn clockwise the switch on temperature wil...

Reviews: