Tele Indication, Type 10” Touch-V1
Index: 00
Date modified: 01/08/2017
OI No.: BA MR 002-00 Fernanzeige V1 EN.docx
Page 10 of 25
4.4
Hydraulic installation
No hydraulic installation.
4.5
Electrical installation
The electrical installations in the room must comply with the requirements of the local (country-specific)
regulations. All plugs on the connecting cables must be screwed or locked to the housing.
ESD SENSITIVE!
The electronic components in the control housing of the Tele Indication Type 10”
Touch-V1 are sensitive to electrostatic discharge. The generally accepted safety
precautions for ESD-sensitive devices must be observed when handling the devices.
The following applies, in particular:
Do not pull or plug in socket connections under voltage.
As the person handling the device, please discharge yourself electrostatically for at least 5 seconds prior
to directly touching the devices, e.g., by touching a grounded part of the system or by wearing an ESD
antistatic wrist strap connected to ground.
5
Commissioning
5.1
Commissioning – comments
The work described here may only be carried out by appropriately trained personnel. Alternatively, the work
can be carried out by persons who have read and understood the entire Operating Instructions. Prior to
commissioning, the installed systems must be checked for proper installation and leaks.
5.2
Commissioning work
The unit is delivered with the factory settings. Adjust the settings to the desired mode of operation and enter
them in the operation data sheet
under
Chapter
For additional settings, see
Chapter 6, Operation