OPERATION
Always disconnect the power source before
attempting to install, service, relocate or maintain the pump. Never touch
sump pump motor, water or discharge piping when pump is connected to
electrical power. Never handle a pump or pump motor with wet hands or
when standing on wet or damp surface or in water. Fatal electric shock
could occur.
Toujours débrancher le cordon d’alimentation
avant d’essayer d’installer, de réparer, de déplacer ou de faire l’entretien
de la pompe. Ne jamais toucher le moteur de la pompe de puisard, l’eau
ou les tuyaux d’évacuation lorsque la pompe est branchée à une source
d’alimentation électrique. Ne jamais manipuler une pompe ou le moteur
d’une pompe avec les mains humides, ou debout sur une surface mouillée
ou humide ou dans l’eau. Cela pourrait occasionner un choc électrique.
Risk of electrical shock! Use a gfci receptacle
to reduce the risk of fatal electric shock. Cutting the cord will void the
warranty and make the pump inoperable.
Risque de choc électrique! Utiliser une prise avec
disjoncteur de fuite à la terre pour réduire le risque de choc électrique.
Couper le cordon annulera la garantie et rendra la pompe inutilisable.
1. After installation, the backup pump will start
when the water level rises above the backup float switch.
2. The control box has a DC charger designed to
shorten the recharging time of your battery, and to
prevent overcharging. In addition, the control box has
a time delay which keeps the pump from repeated,
short cycles when it shuts off. The time delay feature
will allow the pump to run 20-25 seconds after the
switch reaches the off position.
3. The control box contains multi-colored indicator
lights. When AC power is present, the lights will
indicate the charging state, and not reflect actual
battery voltage, particularly with a defective battery. In
order for the indicator light to provide an accurate
reading, steps “a” through “d” must be followed.
Risk of electrical shock! Unplug main
ac pump and the transformer.
Risque de choc électrique!
Débrancher la pompe principale et le transformateur de
courant c.A.
a. After main pump and transformer are unplugged, a
power off alert tone will sound for 30 seconds.
b. Press and release the self test button to activate the back
up pump.
c. When the pump stops, read the charge indicator lights:
Green:
Indicates the battery is fully charged.
Yellow:
Indicates battery partially charged, still operable.
Red:
Battery is completely discharged or defective.
Red blinking:
Battery discharged below level where
pumping can occur. Motor is locked out by controller
until battery is sufficiently charged to run pump.
d. Plug in transformer and main AC pump.
When main AC power is out, and when pump has been
running, the lights will indicate battery status.
4. A chirping sound from the control box will accompany
the red light, indicating that the battery may require
attention or replacement. Voltage is only an indicator
of battery condition and may not reflect the true
condition of the battery. See maintenance for
instruction on assessing battery condition.
5. A single thirty (30) second tone will sound when
power to the system is interrupted and the power
failure light will illuminate. The unit will reset and the
light will go out automatically when power is
restored.
6. A three (3) second tone will sound every time
the
pump starts.
Secure the basin cover and gasket to the basin to
prevent debris from falling into the basin, prevent personal injury, and to
contain gases and/ or odors.
MISE EN GARDE
Fixer le couvercle de cuve et le joint
d’étanchéité à la cuve pour éviter que des débris ne tombent dedans,
prévenir les blessures corporelles et contenir les gaz et les odeurs
Operating Instructions and Parts Manual
7
www.waynepumps.com
WSS30Vn