background image

2

Operating Instructions and Parts Manual

www.waynepumps.com

Installation and Operation 
(Continued) 

3.   To verify discharge hose is free from 

a blockage.
a.  Connect hose to another 

water source such as a faucet. 
If water flows through hose, 
proceed to step 3b. If water is 
restricted, verify discharge hose 
is unwound. Remove all kinks, 
bends or obstructions in hose.

b.  Verify pumping height does NOT 

exceed 20 feet (See Figure 1). If 
pumping height is greater than 20 
feet, this pump will NOT work.

4.   Periodic cleaning of pump is 

required to maintain performance of 
the pump. Follow the cleaning steps 
listed below: 
a.  Unplug the power cord.
b.  Remove the 4 screws in the 

bottom of the base (Reference 
No. 7 in diagram on page 3).

c.  Remove the base (Reference No. 

7).and inlet plate (Reference No. 
6)

d.  Remove the debris and make 

sure the impeller turns freely.

e.  Reinstall inlet plate, base and 

screws.

3.   For best pump performance, unwind 

the hose before starting the pump. 
This will help remove any kinks or 
binds in the hose and allow the unit 
to pump with less restriction.

4.   Set the pump on a hard, flat surface 

in the water. Do not set the pump 
directly on mud or sand surfaces. This 
will cause the inlet screen to clog. 

5.   The water level must be at least 

1-1/2 inches for the pump to prime 
and operate. 

    Water levels less than 1-1/2 inches 

will not allow the impeller to 
contact water and no water will be 
pumped. 

 

Do not 

  handle 

pump with wet hands or 
when standing in water or 
on a damp surface when the 
unit is operating or fails to operate. 
Always disconnect pump power cord 
from power source before handling.

6.   Plug the power cord into a 

grounded 115-volt GFCI power 
outlet. The pump will start operating 
as soon as the power cord is plugged 
into the power outlet.

7.   The pump will remove water down 

to 1/2 inch above the hard surface 
the pump was placed on.

8.   The pump should be turned off once 

the water level reaches the 1/2 inch 
mark.

 

Do not allow pump 

  to run dry. The shaft 

seal depends on water for lubrication. 
Operating pump without water will 
damage the shaft seal and cause pump 
failure.

Maintenance

 

  Always 

disconnect electric supply 
before attempting to install, 
service, relocate or perform 
any maintenance. Failure to do so could 
result in fatal electrical shock.

Minimal service is required for this 
pump. If pump should fail to operate, 
perform the following troubleshooting 
guidelines: 
1.   The motor housing of the pump is 

completely sealed and requires no 
service. 

 

Disassembly of the motor 
housing or alteration of the 
power cord could result in 
fatal electrical shock.

2.   To verify pump is operating correctly.

a.  Disconnect pump from power 

source.

b.  Disconnect discharge hose from 

pump.

c.  Immerse pump in a bucket or tub 

of water.

d.  Plug power cord into a grounded 

115 volt GFCI power outlet. If 
pump operates correctly proceed 
to step #3. If pump does NOT 
operate, unplug power cord 
and proceed to maintenance 
guideline item 4 in this section.

20 Ft. Max.

Water Level

figure 1 - water level