background image

4

For Replacement Parts, call 1-800-237-0987

Please provide following information:

- Model number
- Serial number (if any)
- Part descriptions and number as shown in parts list

Address parts correspondence to:

Wayne Water Systems
101 Production Drive
Harrison, OH 45030   U.S.A.

Ref.
No.

Description

Part
Number

Qty.

1

2

3

4

5

Ejector ASM

Check Valve

Automatic Valve ASM

Float Rod

Float

60115-001

60116-001

60117-001

60118-001

60119-001

1

1

1

1

1

Limited Warranty

For two years from the date of purchase, Wayne Water Systems Division (“Wayne”) will repair or replace, at 
its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found 
upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for 
instructions or see your dealer. Be prepared to provide the model number when exercising this warranty. All 
transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, 
neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written 
instructions.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE 
OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR 
CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED. 

Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or 
limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited 
warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall 
Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not 
limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associ-
ated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime 
costs, or claims of buyer’s customers for such damages.
You 

MUST

 retain your purchase receipt along with this form. In the event you need to exercise a warranty 

claim,  you 

MUST

 send a 

copy

 of the purchase receipt along with the material or correspondence. Please call 

Wayne (800-237-0987) for return authorization and instructions.

DO NOT MAIL THIS FORM TO WAYNE

. Use this form only to maintain your records. 

MODEL NO._______________ SERIAL NO.__________________________  INSTALLATION  DATE_____________ 
  

ATTACH YOUR RECEIPT HERE

Installation Instructions

www.waynepumps.com

Figure 3

3

4

5

1

2

Summary of Contents for EWP10

Page 1: ...this warning could result in fatal electrical shock 3 Verify that the existing AC pump is in good working order If the AC pump is questionable it is recommended that the unit be replaced 4 Remove any...

Page 2: ...pump or pump motor with wet hands or when standing on wet or damp surface or in water Fatal electrical shock could occur Risk of electrical shock Use a GFCI receptacle to reduce the risk of fatal elec...

Page 3: ...ypical Installation with Submersible Pump with a Separate Discharge Pipe EWP10 www waynepumps com Figure 1 Figure 2 Water Supply Main Sump Pump Water Powered Backup Sump Water Supply Main Sump Pump Wa...

Page 4: ...MITED TO TWO YEARS FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allo...

Page 5: ...de desactivar su bomba principal tenga disponibles los medios apropiados para vaciar el sumidero 1 Desconecte la energ a de la bomba principal 2 La bomba debe instalarse usando tuber a de PVC r gido d...

Page 6: ...n el pozo deber a bajar hasta en punto en que la bom ba de sumidero principal se apaga Verifique nuevamente el sistema para comprobar que la bomba de su midero principal y la EWP10 trabajen en conjunt...

Page 7: ...on tuber a de descarga separada EWP10 Figura 1 Figura 2 Suministro de agua Bomba de sumidero principal Bomba de Sumidero de Respaldo Accionada por Agua Suministro de agua Bomba de sumidero principal B...

Page 8: ...NDO GARANTIAS EN RELACION AL MERCADEO O USOS ESPECIFICOS ESTAN LIMITADAS A UN A O A PARTIR DE LA FECHA DE COMPRA ESTA ES LA UNICA GARANTIA DISPONIBLE Y TODAS LAS REPONSABILIDADES CIVILES DIRECTAS O IN...

Reviews: