The ESP15 is a battery operated back-up
sump pump. It does not replace a regular
pump. It is designed to provide protection
in the event household electrical power
fails.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols. 

Danger indicates
an imminently

hazardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 

a potentially

hazardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a 

potentially

hazardous situation which, if not avoided,
may result in minor or moderate injury.

Notice indicates 

important

information, that if not followed, may
cause damage to equipment.

General Safety
Information

Do not use to  pump
flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not use
in a flammable and/or explosive
atmosphere. Pump should only be used to
pump clear water. Fatal injury and/or
property damage could result.

If the basement has water or
moisture on the floor, do not
walk on wet area until all

Operating Instruction and Parts Manual

ESP15 

351203-001 1/06

power is turned off. If the shutoff box is
in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.

All wiring must be 
performed by a

qualified electrician.

Do not expose battery to
sparks or flames as an
explosion or fire could
result.

Battery

acid is corrosive. Avoid
spilling on skin or clothing.
Eye protection must be worn
when handling the battery.

A check valve 
must be used on

the primary sump pump discharge (see
Figure 1)

A ground fault 
circuit interrupter is

required. 

This pump must only 
be used to pump

clear water.  This pump is not designed to
handle effluent, salt water, brine, laundry
discharge or any other application which
may contain caustic chemicals and/or
foreign materials. Pump damage may
occur if used in these applications and
will void warranty.

Battery Requirements

1. Use only a new fully charged 12 volt

deep cycle battery. Electrolyte level
must be checked and maintained in
accordance with manufacturer’s
guidelines.

2. Battery sizes that will fit into the

battery box are 24C, 24VCM, 27C,
27CM and 27F.

3. Battery recharge time will be

different at each installation. Under
normal conditions it will take two to
four days to bring a deep cycle
battery back to full charge after it has

been discharged. If electrical power to
the house is lost more than once a
week, consider keeping a spare, fully-
charged battery to replace an
exhausted battery for the standby
sump pump.

Installation

Installation of this 
unit may take

several hours. Before disabling your
main pump, have ready an appropriate
means of evacuating the sump.

1. Turn power to main pump off.

2. Pump must be installed using 1

1

/

4

” or

1

1

/

2

” rigid PVC piping. A check valve

(not included) 

must

be installed

between the ESP’s tee and the main
pump (see Figure 1).

3. Measure and cut discharge pipe so

that back-up pump is a minimum of 1
inch above the main pump. This will
allow main pump to operate normally
(see Figure 1). 

4. Check the fit of the components

before permanently attaching.  Using
PVC cement, glue tee in place. Note 

12 Volt 
Standby 
Sump Pump

© 2006 Wayne Water Systems

Figure 1

1 inch

min.

4 inch min.

Check

valve

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

For parts, product & service information

visit 

www.waynewatersystems.com

Summary of Contents for 351203-001

Page 1: ...lames as an explosion or fire could result Battery acid is corrosive Avoid spilling on skin or clothing Eye protection must be worn when handling the battery A check valve must be used on the primary...

Page 2: ...chemicals Avoid kinking the cord and replace damaged components immediately 2 Operating Instructions And Parts Manual Operation Always disconnect the power source before attempting to install service...

Page 3: ...main pump If pump fails to operate normally see Troubleshooting guide and correct problem Repeat step 5 Troubleshooting Chart Symptom Possible Cause s Corrective Action Pump won t run Motor hums but p...

Page 4: ...WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL IND...

Page 5: ...tels que l eau sal e la saumure le d charge de buanderie L utilisation de ces produits pourra endommager la pompe et niera la garantie Besoins De La Pile 1 Utiliser seulement des nouvelles piles de 12...

Page 6: ...himiques viter de tortiller le cordon et remplacer toutes les pi ces endommag es imm diatement Fonctionnement Toujours d brancher la source de puissance avant d essayer d installer de r parer de d pla...

Page 7: ...tives Pompe ne fonctionne pas Moteur ronron mais la pompe ne fonctionne pas La pompe fonctionne mais refoule peu ou pas d eau Pompe cycle maintes reprises 1 Raccords ne sont pas s rs 2 Batterie faible...

Page 8: ...OMMERCIALISABILIT ET D ADAPTION UNE FONCTION PARTICULI RE SONT LIMIT ES UN AN COMPTER DE LA DATE D ACHAT CECI EST LA REM DE EXCLUSIVE ET N IMPORTE QUELLE RESPONSABILIT POUR N IMPORTE QUEL ET TOUT DOMM...

Page 9: ...explosivo La bomba debe usarse s lo para bombear agua limpia de lo contrario podr a provocar lesiones fatales y o da os materiales Si hay presencia de agua o humedad en el s tano no camine sobre la s...

Page 10: ...i n correcta debe seguir los pasos de a a d a Desconecte la bomba principal y el cargador sonar una alarma por 30 segundos para indicarle que est n desconectados b Alce y suelte el interruptor flotant...

Page 11: ...hay una v lvula de retenci n instalada y funcionando entre la descarga de la bomba primaria y la conexi n en T de la bomba de sumidero de reserva 2 Revise si hay obstrucci n y remu vala si es necesar...

Page 12: ...r las instrucciones suministradas por escrito por la compa a Wayne NO HAY NINGUNA OTRA GARANTIA EXPRESA O IMPLISITA INCLUYENDO AQUELLAS SOBRE VENTA O USOS ESPECIFICOS Y LAS GARANTIAS ESTAN LIMITADAS A...

Reviews: