background image

The list includes most of the common cases, but not the results of defective 
unit, crafts or materials in the unit. 
If all troubleshooting steps have been exhausted and the issue is still 
occurring, please feel free to reach out to Waykar Customer Seryice to get 
further assistance.

Is the Full Tank indicator blinking? 

This product does not apply to 
over hot or cold environment, the 
machine will automatically enter 
the protection mode. It is a normal 
phenomenon.

When running under lower 
ambient temperature, the machine 
will automatically defrost, which is 
a normal phenomenon. It will 
restart dehumification again until 
the defrosting process finished.

It is normal the compressor 
ceases while defrosting process. 
Wait until the process finished, it 
will restart dehumidification again.

Is the room humidity lower or 
reaching the preset humidity 
level?
(When the room humidity has 
reached the preset level, the 
dehumidifier will enter Standby 
Mode and the indicator on LCD 
will flash. )  

Please set the humidity decrease 
by 5% than the room humidity or 
set the humidity to 30%.

This is to prevent the frequent 
start of the machine. Does the 
machine stop working just now? 

The dehumidifier is designed to 
work in the humidity range of 30%-
80%. Above or below this range, it 
will not work. 

, it

Summary of Contents for YDA-858E

Page 1: ...Home Dehumidi er Please read the manual carefully before using the unit YDA 858E USER MANUAL...

Page 2: ......

Page 3: ...use of the dehumidifier Our dehumidifiers are widely used in family bedrooms bathrooms basements offices and storage rooms etc The dehumidifiers from provide quick and efficient operation to Waykar re...

Page 4: ...nternal damage it is very important to keep refrigeration units like this one upright throughout their journey Please leave it standing upright and outside the box for 24 HOURS before plugging it in B...

Page 5: ...TABLE OF CONTENTS Safety Instructions Parts Description Common Faults and Solutions Warranty Contact Us 16 15 14...

Page 6: ...The machine power wiring must be in accordance with national wiring rules and power line should be connected to the reliable external Earth Line The fixed wiring of the machine connection must be equ...

Page 7: ...Drainage Hose Outlet PARTS DESCRIPTION...

Page 8: ...to turn the machine on or off Up Button Press to set the humidity up Down Button Press to set the humidity down Timer Button Press to initiate the auto start and auto stop feature Speed Button Press t...

Page 9: ...r turn on the machine automatically by the timer Press the TIMER button you will enter TIMER setting mode Press UP button to select the timer increase by 1 hour press Down button to decrease by 1 hour...

Page 10: ...automatically determine whether there is a presence of frost If any frost exists it will defrost automatically Defrost Action The fan runs at high wind speed when the compressor stops and the screen d...

Page 11: ...e is running the indicator will display continuously from left to right in order When running at low wind speed the fan indicator will rotate in a lower speed but in a high speed when high wind speed...

Page 12: ...splay the alarm code If you power off the machine it can be restarted after powered again 2 When one of the above malfunctions occurs the buzzer will alarm for a few seconds Press any key during the a...

Page 13: ...to the unit Door Water Tank Open the door Take the water tank out from the bottom Empty the water tank Put the water tank back in place and close the door the WATER FULL indicator will go out Note If...

Page 14: ...or Connect the power supply to start the operation The outlet of the water hose should be lower than the continuous drainage port by more than 3 9 inches and the water hose cannot be bent Note The dia...

Page 15: ...Please use a soft and slightly wet textile or cloth to clean it 3 Slowly insert the filter back to the machine body...

Page 16: ...y defrost which is a normal phenomenon It will restart dehumification again until the defrosting process finished It is normal the compressor ceases while defrosting process Wait until the process fin...

Page 17: ...ure Please wait until the temperature rises to above 5 or higher Clean up the dirt or lint on the air outlet and intake Continuous Mode Do Not set the humidity too low Typically 40 50 are good for use...

Page 18: ...k Re install the water tank properly Move the float and let it swing freely If the dehumidifier is still not working properly as expected and the troubleshooting steps or solutions above may not resol...

Page 19: ...xtile to wipe gently do not shoot the water directly Please clean the filter every two weeks do not use hot water above 104 F alcohol gasoline or toluene When continuous drainage the drain hose must b...

Page 20: ...P 15...

Page 21: ...ly if damage is caused by other factors including but without limitation of Please fill out all required fields and inlcude your Order ID Date of Purchased if applicable Order Number ready Warranty Ex...

Page 22: ...We are expecting to see our products fulfill your life and hear your voice Your satisfaction means a lot to us Please tag us if you share a snap on your social media...

Reviews: