IMPORTANT:
After mounting the LED sensor light, apply silicone sealant
completely around the perimeter of the cover plate where the back
of the cover plate meets the mounting surface. Silicone sealant
prevents water from seeping into the junction box.
CAUTION:
Make sure motion detector head is not UPSIDE DOWN! Rotate the
motion sensor so that controls face toward to
the detection areas.
ADJUSTING THE SENSOR HEAD:
Aim sensor head toward desired detection area and make sure
sensor head is positioned with controls facing toward the ground.
You can adjust the sensor head up and down, left to right for
desired coverage area.
RECOMMENDED INSTALL HEIGHT:
6.5-8.25 feet above the ground.
At such a height, the fixture will provide a detection distance of up to 59 feet at 77 degrees fahrenheit.
The sensor will be more sensitive to motion across than motion towards it directly.
4
Motion Sensor Horizontal
5ft.
Detection Coverage
Height
Sensor
Least Sensitive Most Sensitive
Motion
Motion
7ft.
Motion Sensor Downward 5°
Detection Coverage
Height
9ft.
Motion Sensor Downward 10°
Detection Coverage
Height
Installation is now complete. Turn on power at circuit breaker and flip wall switch to ON position. Wall switch must
remain in the ON position for the motion detector to work properly (include daytime).
SENSOR ANGLES 240°