background image

TOOLS REQUIRED (not included)

LED MOTION SENSOR LIGHT 

 

Flathead Screwdriver

Screwdriver

Silicone Sealant

Step Ladder

Eye Protection

Phillips

Pliers

2

PARTS LIST

NOTED:

1. AT AN AMBIENT TEMPERATURE OF 77 DEGREES FAHRENHEIT, RH 30%-80%

,

THE DETECTION DISTANCE

    IS AT MAX. (UP TO 49FT.). AS THE TEMPERATURE INCREASES OR DECREASES, THE DETECTION

    DISTANCE WILL BE AFFECTED.

2. TO REDUCE POSSIBLE NUISANCES, DO NOT MOUNT THE FIXTURE NEAR A HEAT SOURCE LIKE AN AIR

    CONDITIONER, VENT OR FURNACE EXHAUST, OR IN A DIRECTION FACING ANY REFLECTIVE OBJECT OR

    OTHER NEARBY LIGHT SOURCE. 

3. NO ANY REFLECTIVE OBJECT CAN BE ALLOWED WITHIN 1.5M RADIUS OF THE SENSOR HEAD,

    OTHERWISE, IT WILL CAUSE FLASHING LIGHTS.

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product.

PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN!

WARNING

   Shut off power at the circuit breaker or fuse panel before removing the old fixture or installing the new one.

   LED electronics can be damaged by electrostatic discharge (ESD) shock. Before installation, discharge yourself by 

   touching a grounded bare metal surface to remove this hazard.

   To avoid damage, do not remove the clear lens over the LED module.

CAUTION

DO NOT USE THIS FIXTURE WITH A DIMMING CIRCUIT.

If you currently have dimmer controls, you will need to remove them and replace them with regular electrical switches.

If you have a three-way dimmer, you will have to replace it with a regular three-way switch. If you are unfamiliar with

electrical installations, it is recommended you have a qualified electrician do your installation.

IMPORTANT SAFETY INSTRUCTIONS

 1.Turn power OFF before installing or servicing.

 2.Do NOT touch or install fixture while in contact with standing water.

 3.Do NOT remove the protective LED lens.

 4.Do NOT look directly at lighted LEDs for any length of time.

 5.Do NOT leave bare wires exposed outside the wall canopy enclosure.

 6.Electrical requirements: 120V, 60Hz

 7.Suitable for wall or eave mounting onto recessed or round surface mounted electrical boxes rated for wet location

    Not suitable for ground mount electrical boxes.

 8.Do NOT allow the sensor head to touch the LED head housing. 

    Maintain at least 1 in. spacing between the LED heads and the sensor head.

 9.For proper operation and protection against water damage, 

    the motion sensor adjustment controls MUST be facing downward.

10.Do NOT mount below 5 ft.

A: Screw (Painted Green) / Qty. 1 

B: Machine Screw / Qty. 2 

B1: Machine Screw / Qty. 1

C: Ring/Qty. 1    Nut / Qty. 1 

D: Wire Nuts / Qty. 3 

E: Crossbar / Qty.1

F: EVA Gasket / Qty.1

M4*60MM

M4*25MM

Reviews: