WayCool 1HP MFA Series User Manual Download Page 6

Description

The WayCool® evaporative cooler is a completely self-contained, portable unit capable of delivering 40 MPH
velocity of air with a temperature drop of up to 20 degrees F. The unit is composed of:

• Level-controlled water supply system
• Cooling pad assembly
• Motor-driven blower and ductwork
• Controls
• Frame and housing

The reservoir is made of high impact ABS plastic and holds approximately 24 gallons at normal operating level
(about 5" deep).

A float-operated valve automatically maintains proper water level when the unit is connected to a water supply.

The reservoir rests on, and is fixed to, an aluminum cradle. The reservoir, in turn, is secured to the aluminum
frame. Four casters (two locking, two regular) are attached to the underside of the aluminum cradle.

A pump draws water from the reservoir and discharges it through the vinyl hose to the PVC pipes located above
the cooling pads. The PVC pipes distribute water onto the top of the cooling pads; saturating them. Excess
water drips back into the reservoir through the holes in the cooling pad support channels.

The cellulose cooling pads sit in support channels and are held in place by plastic retaining grates. The grates
also help prevent damage to the cooling pads. Two pad sections fit in each side of the unit (total eight sections)
to totally enclose the unit.

The blower is hung from the top of the frame and powered by a belt-driven 1HP electric motor. The blower
draws room air through the cooling pads where it picks up moisture and cools by evaporation. The blower then
discharges the cooled air through the spout.

It is important the cooled space has sufficient air openings so the warmer air can flow out and be
replaced by the cooled air. A closed-in space or high humidity will reduce the cooling effect. See Unit
Placement and Other Considerations in the "Operation and Maintenance" section of this manual.

A screen covers the discharge duct to prevent foreign objects from entering the blower. A threaded rod screws
through a threaded brace above the screen to hold the spout in position. A plastic knob secures the spout to the
rod. The spout is made of a tough, durable plastic and can be manually rotated 360 degrees to provide cool air
in any direction without moving the unit.

Water weighs about eight pounds per gallon, so when the unit is full it weighs over 375 pounds. During
setup and before startup, place the unit in the desired location and then fill the reservoir. Do not attempt
to lift the unit once it is filled and be careful to avoid spills when moving it, even over smooth ground.
Do not try to push it over rough or soft ground as you can overstress the wheels and frame and cause
structural and component damage, which is not covered by the warranty.

CAUTION 

Never leave unit unattended while in operation. Do not allow unit to run dry.

6

Summary of Contents for 1HP MFA Series

Page 1: ...Portable Evaporative Cooler WayCool 1HP MFA Series USER S MANUAL WC 1HPMFA WC 1HPMFA360 WC 1HPMFAOSC WCG 1HPMFA...

Page 2: ...Splattering in front 14 Leaking from the bottom 14 OPTIONS AND ACCESSORIES 15 Pneumatic wheels 15 Water conditioner and cleaner 15 Air filters 15 Aluminum grates 15 Oscillating spout 16 WARRANTY 17 Ta...

Page 3: ...oling effect In an evaporative cooler the cellulose cooling pads take the place of your skin water instead of perspiration wets them and a fan moves the air The air blows across the cooling pads and e...

Page 4: ...t Signal Words are used in conjunction with the safety alert symbol to identify the severity of the warning CAUTION indicates an imminently hazardous situation which if not avoided COULD cause damage...

Page 5: ...careful and wear gloves when you reach under the frame to inspect the PVC pipes and mesh socks A GFCI Ground Fault Circuit Interrupter is recommended for use with this product If pads and grates are r...

Page 6: ...ose the unit The blower is hung from the top of the frame and powered by a belt driven 1HP electric motor The blower draws room air through the cooling pads where it picks up moisture and cools by eva...

Page 7: ...reservoir can also be filled manually with a hose or bucket if a hose connection is impractical Simply remove the cap and pour the water directly into the reservoir When you fill the reservoir manuall...

Page 8: ...irt builds up water flow to the cooling pads is reduced and performance decreases The clear filter housing is threaded and screws into the filter body for easy removal to access the screen A dirty wat...

Page 9: ...hen wet Always run the unit with the plastic retaining grates in place and handle them carefully when you clean them Crushed cells reduce the total airflow through the unit and therefore lowers its co...

Page 10: ...which do not require lubrication A belt tensioner is connected to a bracket on the motor A rubber foot at one end rests against the blower bracket that is attached to the blower casing When the lockin...

Page 11: ...st saturate the cooling pads then switch to LOW COOL or HIGH COOL to begin cooling Control Switch 11 Operation and Maintenance UNIT PLACEMENT AND OTHER CONSIDERATIONS The WayCool should be placed at o...

Page 12: ...hand on the pad s inside your other hand on the outside and lifting the pad up and out from the bottom 6 Inspect the entire unit for shipping damage 7 Ensure the fan belt is attached to the motor and...

Page 13: ...unit make sure there are no obstructions that could disrupt or block the airflow Make sure the unit is level at all times Keep the unit at least three feet away from walls or other obstructions that...

Page 14: ...cover on the unit 5 Remove the top cover and set it aside 6 Locate the four PVC pipes in the top metal channel Each PVC pipe is secured to the Y connector by a single screw Remove this screw from all...

Page 15: ...to be present in some water sources Place the tab under the float valve water outlet for fast effictive odor control Place the tab next to the pump for longer lasting odor control CLEANER WayCool cle...

Page 16: ...e replaced IF SPOUT APPEARS TO JUMP WHILE OSCILLATING 1 The spout may be fastened too tight against the top of the WayCool The nut above the brace should be loosened to allow 1 16 clearance between th...

Page 17: ...opriate or regular maintenance of the product b Loss of time inconvenience loss of use of the product or other consequential or incidental damages c Parts that need replacement due to normal wear and...

Page 18: ...www schaeferfan com 2011 Schaefer Ventilation Equipment M WC1HPMFA 9 6 11...

Reviews: