Seite 37 / 48
5.15. Analog Out Menu
This menu defines the basic settings of the analog output. This function is only available for devices with
option A0.
SOURCE 1
This parameter defines the reference source for PRESELECTION 1
INPUT 1
the reference source is input 1
INPUT 2
the reference source is input 1
LINKAGE 1 – 2
the reference source is the result of the linking of input1 and input 2
INPUT 1 TOTAL
the reference source is input 1 with totalization
INPUT 2 TOTAL
the reference source is input 1 with totalization
LINKAGE TOTAL
the reference source is the result of the linking of input1 and input 2 with
totalization
The totalization depends on the operation mode. See chart in chapter IN 1 Totalization.
ANALOG FORMAT
This parameter defines the output characteristics. The analogue output is proportional to the display value.
With setting ANALOG FORMAT (-10 … +10 V) in MODE COUNTER the polarity of the analog output
depends on the polarity of the display value.
0
-10…10V
-10 … +10 V
1
0…20MA
0 … 20 mA
2
4…20MA
4 … 20 mA
ANALOG START
This parameter defines the start value of the analog conversion. This start value is corresponding to the
display value for an analog output of 0 V or 0/4 mA.
-99999999
Smallest start value
0
Default value
+99999999
Highest start value
ANALOG END
This parameter defines the end value of the analog conversion. This end value is corresponding to the
display value for an analog output of (+/-) 10 V or 20mA.
-99999999
Smallest end value
10000
Default Wert
+99999999
Highest end value