![Waycon SX Series Installation Manuals Download Page 4](http://html1.mh-extra.com/html/waycon/sx-series/sx-series_installation-manuals_3927362004.webp)
ELECTRICAL CONNECTION SSI
SX50: Cable output 1⁾
Signal
GND
+V
C+
C-
D+
D-
SET
DIR
Status
H
Cable colour
WH
BN
GN
YE
GY
PK
BU
RD
VT
shield
SX80, SX120: Cable output 1⁾
Signal
GND
+V
C+
C-
D+
D-
SET
DIR
Status
H
Cable colour
WH
BN
GN
YE
GY
PK
BU
RD
BK
shield
1⁾ isolate unused wires individually before initial start-up
SX80, SX120: Connector output M12, male, 8 pins
Signal
GND
+V
C+
C-
D+
D-
SET
DIR
H
Pin
1
2
3
4
5
6
7
8
shield
SX80, SX120: Connector output M23, male, 12 pins
Signal
GND
+V
C+
C-
D+
D-
Pin
1
2
3
4
5
6
Signal
SET
DIR
Status
n. c.
H
Pin
7
8
9
10, 11, 12
shield
1
2
5
4
3
7
6
8
2
1
5
6
7
3
4
8
9
10
11
12
ELECTRICAL CONNECTION CAN
open
SX50: Cable output 1⁾
Signal
GND
+V
CAN_L
CAN_H
CAN_GND
Cable colour
WH
BN
YE
GN
GY
SX80, SX120: 2 x Connector output M12
Bus OUT (female)
Bus IN (male)
Signal
GND
+V
CAN_L
CAN_H CAN_GND
GND
+V
CAN_L
CAN_H CAN_GND
Pin
3
2
5
4
1
3
2
5
4
1
2
1
3
4
5
1
2
4
3
5
SX80, SX120: cable gland radial (removable bus terminal cover)
Bus OUT
Bus IN
Signal
GND
+V
CAN_L
CAN_H CAN_GND
GND
+V
CAN_L
CAN_H CAN_GND
Acronym
0 V
+V
CL
CH
CG
0 V
+V
CL
CH
CG
1⁾ isolate unused wires individually before initial start-up