2
Number*
Symbol
Description
1
T1
Connection for temperature sensor, Outdoor temperature sensor
2
T2
Connection for temperature sensor, Flow, heating circuit 1
3
T3
Connection for temperature sensor, Return, heating circuit 1
4
T4
Connection for temperature sensor, Flow, heating circuit 2
5
T5
Connection for temperature sensor, Return, heating circuit 2
6
S1/C/S2
Servo motor, heating circuit 1
7
S3/C/S4
Servo motor, heating circuit 2
8
O1/GN
Universal programmable input / output 1
9
O2/GN
Universal programmable input / output 2
10
+U/A/B/GN
ROXi bus
11
AO/GN
Analog output 0-10V
12
PO
PWM output (To be used with “GN” for analog output )
13
PI
PWM input (To be used with “GN” for analog output)
14
VFR 1
Connection to voltage-free relay 1
15
VFR 2
Connection to voltage-free relay 2
16
P1/N/PE
Connection to pump relay 1 (230V)
17
P2/N/PE
Connection to pump relay 2 (230V)
18
L/N/PE
Connection to 230V supply
19
A1 – A8
Actuator outputs 1-8 (for 1 or 2 PC of thermal acutator 24V 1W/PC)
20
-
Internal connection between Control Unit(IV) and Extension Unit (V, VI)
21
A9 – A16
Actuator outputs 9-16 (for 1 PC of thermal acutator 24V 1W/PC)
22
A/B
Connection to 24V voltage-free relay
23
C
Connection to voltage-free relay C, AC 24-230V, 1A each
24
D
Connection to voltage-free relay D AC 24-230V, 1A each
25
E
Connection to voltage-free relay E AC 24-230V, 1A each
26
F
Connection to voltage-free relay F AC 24-230V, 1A each
Installation and connection of the Wavin Sentio Control Unit and Extension Units may only be carried out
by an authorized installer.
* See page B
Ports CCU and EUs
2
Summary of Contents for Sentio
Page 1: ...Control system Underfloor heating cooling WAVIN SENTIO Quick Guide January 2020...
Page 2: ...A A A F I H H H J L M N N L L N G G O K K F B B B C D E A...
Page 10: ...Enroll procedure thermostat sensors I...
Page 11: ...J Choose profile System Installer settings Hardware profile Change profile 3 2 4 1...