  Operation Of Key Pads 

1. The unit will beep twice once plugged into the power socket. 

2. Press the “ON/OFF” button to turn on the unit. The deflector will startup automatically and at this point, 

the unit is in the status of constant dehumidifying and high speed running. 

     

1

The blue backlight will illuminate and turn off after 15 second.     

    2

The LCD display shows the working mode and status of unit.   

3

The LCD display shows the ambient humidity and temperature.   

4) Press the “ON/OFF” button again, the unit will stop working and the deflector close. 

 

3. MODE:   

Set up continuous & automatic dehumidifying modes and air speed by using the MODE key. Select or 

change  to  the  desired  mode  (the  indicator  light  will  illuminate  accordingly),  then  press  “Setting”  to 

change the running mode and automatic dehumidifying ratio. 

 

(1)  When  the  automatic  dehumidification  indicator            illuminates,  press  “Setting”  to  make  it 

circulate  among  60%RH-65%RH-70%RH-75%RH-80%RH-40%RH-45%RH-50%RH-55%RH 

-60%RH

·

·

·

·

·

 

 

1

When  entered  into  automatic  dehumidification,  if  you  press  “Setting”,  the  continuous 

dehumidifying mode will be cancelled. 

  2

Press “Mode” or three seconds after pressing “Setting”, the desired humidity ratio is set 

and the indicator light switches off. 

3

When sensor detected ambient humidity is 1% lower than your setting, compressor shut 

off and fan works at low speed. If ambient humidity is 5% higher than the setting, the 

dehumidification is activated again. 

 

 

(2) When the wind speed  

  indicator  illuminates,  press  “Setting”  to  select  your  desired  fan 

blower setting of “High speed” level or “Low speed” level. 

 

1)  It  shows  ‘L’  when  working  at  “Low  speed”  level  and  shows  ‘H’  when  working  at  “High 

speed” level. 

2) Press “Mode” or three seconds after pressing “Setting”, the wind speed is set. 

3) When the wind speed is set, dynamic patterns rotate. 

4) When the sensor detects that the ambient humidity is lower than your desired setting, the 

fan works at low speed. 

5) When the sensor detects that the ambient temperature exceeds 32

°

C, the fan works at 

the “High speed” level automatically. 

 

 

3

When the continuous dehumidification indicator          illuminates, press “Setting” to make the 

unit run at the continuous dehumidification mode. 

4. SETTING

 

When the indicator light illuminates according to your desired mode, pressing “Setting” will confirm the 

running mode or automatic dehumidifying ratio. 

 

Summary of Contents for WL-YL-2612B

Page 1: ...User s Manual Model No WL YL 2612B...

Page 2: ...unctions of Control Panel Key Pads LCD Display Operation of Key Pads Automatic Defrosting Water Tank Full Warning Processions Of Abnormal Compressor Protection Of Extremely Low High Temperature Failur...

Page 3: ...re the inlet and outlet ventilation is not blocked at any time 2 To avoid an electric shock avoid placing the unit near window or in a bathroom 4 Do not operate this unit in an explosive or corrosive...

Page 4: ...6 Unplug the appliance during cleaning Ambient Environment For Operating 1 Working environment Lowest ambient temperature 5 C 40 RH Highest ambient temperature 35 C 90 RH 2 Always operate the unit ind...

Page 5: ...Component Diagrams Air deflector Control panel...

Page 6: ...tch the power button on the unit to start up 2 Press mode to select the desired working mode and the corresponding indicator light will illuminate 3 Press Setting to select the desired running mode an...

Page 7: ...fying mode will be cancelled 2 Press Mode or three seconds after pressing Setting the desired humidity ratio is set and the indicator light switches off 3 When sensor detected ambient humidity is 1 lo...

Page 8: ...r To ensure the unit performs well in these conditions an automatic defrost function is fitted to the appliance 1 When a room temperature drops down to 16 or less the compressor works for 25 minutes d...

Page 9: ...start the unit 2 After the unit has experienced extremely low high temperature the appliance will not keep its memory function when restart Failures Of Humidity Temperature Sensor 1 When an error betw...

Page 10: ...he last set mode 2 If the power supply is shut off into a protection mode the appliance will not recover back to the last set mode Continuous Drainage Remove water plug and connect with PVC hose with...

Page 11: ...rection as shown on figures Use a vacuum cleaner or water to clean and then put it in ventilated place until it s dry Always switch off and unplug before moving this unit When packing away this unit f...

Page 12: ...d 220 240VAC 50Hz Moisture removal 12 L D 30 RH80 Dehumidifying Power 255W 30 RH80 Max Power Dissipation 300W 35 RH90 Dehumidifying Air Volume L 80m3 h H 100 m3 h Refrigerant R134a 120g Capacity of Wa...

Reviews: