Important Safe Guards 

 

 
 

1

Please be sure your electricity is fully working 

 
3

To reduce a fire risk, ensure the unit is not placed 

next to a high temperature appliance. 

 

 

 

 

 

 

 

 

 

 

 

 

5

Do  not  allow  children  to  operate  this  unit.  Never 

disassemble  the  unit,  and  never  try  to  carry  out 

repairs or adjust the unit yourself. 

7

Do not use the unit when mounted on a slant. If for 

any reason the unit falls over, pull out the plug at 

once. 

 

 

 

 

 

 

 

 

 

 

9

Make  sure  the  inlet  and  outlet  ventilation  is  not 

blocked at any time. 

 

 

 

 

 

 

 

 

 

2

To  avoid  an  electric  shock,  avoid  placing  the  unit 

near window or in a bathroom. 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Do not operate this unit in an explosive or corrosive 

environment. 

6

Operate  this  unit  on  a  horizontal  surface  to  avoid 

vibration and noise. 

8

When  positioning,  ensure  there  is  30  cm  of  clear 

space on each side of the unit. 

 

 

 

 

 

 

 

 

 

 

10

Never allow water to spray onto the unit. Contact 

with water may cause malfunction and electric shock. 

 

 

 

 

 

 

 

 

 

 

Do not install and use the unit before carefully reading this instruction guide. Please 
retain this manual for product warranty and future reference.

 

Summary of Contents for WL-YL-2612B

Page 1: ...User s Manual Model No WL YL 2612B...

Page 2: ...unctions of Control Panel Key Pads LCD Display Operation of Key Pads Automatic Defrosting Water Tank Full Warning Processions Of Abnormal Compressor Protection Of Extremely Low High Temperature Failur...

Page 3: ...re the inlet and outlet ventilation is not blocked at any time 2 To avoid an electric shock avoid placing the unit near window or in a bathroom 4 Do not operate this unit in an explosive or corrosive...

Page 4: ...6 Unplug the appliance during cleaning Ambient Environment For Operating 1 Working environment Lowest ambient temperature 5 C 40 RH Highest ambient temperature 35 C 90 RH 2 Always operate the unit ind...

Page 5: ...Component Diagrams Air deflector Control panel...

Page 6: ...tch the power button on the unit to start up 2 Press mode to select the desired working mode and the corresponding indicator light will illuminate 3 Press Setting to select the desired running mode an...

Page 7: ...fying mode will be cancelled 2 Press Mode or three seconds after pressing Setting the desired humidity ratio is set and the indicator light switches off 3 When sensor detected ambient humidity is 1 lo...

Page 8: ...r To ensure the unit performs well in these conditions an automatic defrost function is fitted to the appliance 1 When a room temperature drops down to 16 or less the compressor works for 25 minutes d...

Page 9: ...start the unit 2 After the unit has experienced extremely low high temperature the appliance will not keep its memory function when restart Failures Of Humidity Temperature Sensor 1 When an error betw...

Page 10: ...he last set mode 2 If the power supply is shut off into a protection mode the appliance will not recover back to the last set mode Continuous Drainage Remove water plug and connect with PVC hose with...

Page 11: ...rection as shown on figures Use a vacuum cleaner or water to clean and then put it in ventilated place until it s dry Always switch off and unplug before moving this unit When packing away this unit f...

Page 12: ...d 220 240VAC 50Hz Moisture removal 12 L D 30 RH80 Dehumidifying Power 255W 30 RH80 Max Power Dissipation 300W 35 RH90 Dehumidifying Air Volume L 80m3 h H 100 m3 h Refrigerant R134a 120g Capacity of Wa...