P.
12
www.wavecontrol.com
User’s Manual
Personal equipment WaveMon
Two different log intervals may be defined.
This allows you to define a different interval for
when the field strength is low and when the field
strength is high. Where the field strength is low,
we do not need to memorise so much negligible
information, saving memory space and battery
life. Where the field strength is high, however, we
can define a shorter log interval to have more
relevant information for later processing.
The log interval defines how often a measurement
is stored in memory. This interval does not
affect how the measurement is taken or the
warnings given to the user. The device will always
measure and calculate the average every second,
regardless of the log interval value.
7.
LOG INTERVAL AND AVERAGE
8.
GPS AND ALTIMETER OPTION
As optional features, the
WaveMon
can have an
internal GPS receiver and an altimeter so that
each reading can be automatically associated
with a geographical position. The altimeter allows
determination of the relative altitude in respect
of the position where the device was initially
switched on.