Wavecom TnT Titan 20A User Manual Download Page 10

10

TnT Titan 20A

User Manual

Wavecom

You can now set up your User Account - this is your individual profile. If you are the first or the only Test and 

Tag technician at your organisation, you should set yourself as an ‘ADMIN’ user, which will allow you to use the 

full features of WinPATS. Technician users have reduced access to features - this is designed for organisations 

with multiple technicians and/or multiple sites.

Once your details are complete, tap ADD to create your account. Confirm your details are correct, then tap 

CONFIRM to finish registering your user account.

When you start WinPATS for the first time you’ll be required to perform a data sync. This creates a new cloud 

database for you or connects your WinPATS App to your company’s existing database. If your database has 

many items, this may take up to 5 minutes, but usually only takes a few seconds.

Connecting via Bluetooth

To control your TnT Titan via Bluetooth, you will need to perform a short setup procedure. Ensure you have 

both your tablet with WinPATS installed, and your TnT Titan in front of you.

Go to the Bluetooth settings in your Tablet’s settings menu

Ensure that Bluetooth is enabled, then select your TnT Titan from the list of available devices (ensure you 

select the correct tester by referring to the serial number. Your TnT Titan’s serial number is located on the 

bottom of your tester, and on the rear cover of this booklet).

You may now be prompted to pair your two devices using a PIN code. If so, your TnT Titan will display a code on 

the screen. Enter this code into WinPATS and tap OK. You will be asked to confirm the connection - tap Confirm 

after checking the details are correct. 

Note: If you have any issues with the PIN code, you can disable this function from the TnT Titan settings menu. Power on 

your TnT Titan, then hold Enter and press F2 to open the settings menu. Navigate to ‘Bluetooth Configuration’ and press 

Enter. When prompted with ‘Use Security PIN for Bluetooth’ select ‘Disable’ by pressing F3.

Go to the WinPATS App

To connect your TnT Titan, go to the Test menu in the WinPATS App (at the top of the screen). You should be 

prompted to connect a Wavecom Appliance Tester as soon as you open the Test Menu for the first time. Tap 

‘BLUETOOTH’ to begin the Bluetooth setup process.

WinPATS

USB OTG

Cable

USB-A to Micro USB 

Cable

USB-A

For devices with USB-C port, a USB-C OTG 

Cable is required (not supplied with Tester)

Micro USB

Micro USB

Summary of Contents for TnT Titan 20A

Page 1: ...Wavecom User Manual Certificate of Warranty and Product Support Information TnT Titan 20A Portable Appliance Tester...

Page 2: ...oduct that proves to be defective This warranty does not apply if the product has been damaged by accident abuse misuse or mis application or as a result of service or modification by anyone other tha...

Page 3: ...petent Person as well as any additional legislation or rulings in different states If in doubt the manufacturer suggests the user contact their responsible authority For maximum safety always ensure t...

Page 4: ...ting Menu Main Menu A 17 TnT Titan Testing Menu Main Menu B 18 Meter Mode Not available in Battery Mode 23 Specifications 25 Technical Information 26 Visual Inspection 26 Class 1 Earthed Appliance Con...

Page 5: ...G Adapter IEC Test Lead 500mm Orange USB A to USB B Interface Cable Earth Lead with Alligator Clips 1800mm Black IEC Power Cable 10A units IEC 20 10 Power Cable with Circuit Breaker 20A Units 24 Month...

Page 6: ...Internal lithium ion battery 98Wh 6700mAh can power the TnT Titan for around 3000 sets of tests The battery is charged simply by plugging the TnT Titan into mains power and it takes around four hours...

Page 7: ...ition as described in the current AS NZ 3760 2010 Standard and in addition to any other local legislation or jurisdictions as may be relevant in your State A person competent to undertake Inspection a...

Page 8: ...ATS and may slow down the app significantly We strongly recommend that you do not install other apps on this tablet to ensure the stable operation of the WinPATS App Before using your tablet with WinP...

Page 9: ...this allows you to use the full set of WinPATS features Now fill in your details a valid ABN is required to register a new company You should use the address and contact details of your head office On...

Page 10: ...et s settings menu Ensure that Bluetooth is enabled then select your TnT Titan from the list of available devices ensure you select the correct tester by referring to the serial number Your TnT Titan...

Page 11: ...our TnT Titan as shown Connecting your TnT Titan to your Tablet via USB To connect your TnT Titan to your tablet via USB you will need A USB A to USB B cable Included A Micro USB to USB A cable Includ...

Page 12: ...he user but keep the profile or delete the user To add a new User tap the symbol next to the dropdown menu Fill out the form including selecting a profile picture and assigning Admin permissions if re...

Page 13: ...ltiple ways an item can be tested using WinPATS This part will cover the two most common methods Both of these methods require that your TnT Titan to be connected to your tablet see above Connecting v...

Page 14: ...find the item in your Inventory Side Menu Database Inventory Once you are on the Item Information screen review the Assigned Test Sequence and ensure the correct test will be conducted Set up the item...

Page 15: ...e which may be useful for troubleshooting but you can set up your scanner using the following instructions We recommend that you ensure the scanner is fully charged before using it on site First ensur...

Page 16: ...ing a test the LEDs will flash white TnT Titan is running on battery power active Bluetooth connection LEDs will flash blue during tests TnT Titan is running on mains power and is charging no Bluetoot...

Page 17: ...Mains Test Refer to Integrated Test section Integrated NCNT Test Refer to Integrated Test section Earth Bond Test 200mA 200mA test current pass level less than 1 Insulation Test 250V or 500V pass lev...

Page 18: ...testing especially on surge protected powerboards If unsure always refer to the AS NZS 3760 2010 Standard Should it still fail remove it from service Lead Test Extension Lead Test Menu A F3 Note Exte...

Page 19: ...erating ensure the equipment is firmly secured to eliminate the possibility of causing injury or damage This function will power the appliance on and in the case of appliance with movable parts these...

Page 20: ...ing is 20sec The value for the leakage runtime is also used for the power test Caution Before operating ensure the equipment is firmly secured to eliminate the possibility of causing injury or damage...

Page 21: ...efault setting on all new units Trip Time Testing This test is designed to trip RCD devices at a fixed current and to determine the trip time of the RCD device During an RCD Trip Time test the TnT Tit...

Page 22: ...Titan has the correct settings for the type of RCD 4 Once your TnT Titan is set up correctly select either the 0 Positive or the 180 Negative Phase to test Both phases should be tested and after the...

Page 23: ...4 Test available in Meter Mode Meter Mode Measures and displays volts in AC Current in Amps Power Measurement in Watts and VA in Volt AMPS Typical Applications Measuring the Power of a bar heater or e...

Page 24: ...Amps VA The power in Watts is the real power drawn by the equipment Volt Amps are called the apparent power and are the product of the voltage applied to the equipment times the current drawn by the...

Page 25: ...Measurement 0 1 to 10 0M Continuity Polarity Test 250VAC check continuity and polarity of leads Displays Pass Fail Leakage Test Leakage Current 0 to 30 0mA at 200 to 265V Earth Leakage Test 240VAC Mai...

Page 26: ...vices and systems are in good working order i e overload latches buttons No dust or dirt obstructs any exhausts or ventilation outlets All controls are working properly and are secure and aligned Impo...

Page 27: ...ction against electric shock which is equivalent to double insulation Testing of Electrical Equipment Many testing personnel have some reservations in testing sensitive electronic equipment using a 50...

Page 28: ...re Note Test time with the new TnT Titan can now be user controlled This function enables testing personnel to extend the Earth Bond test time by 30 second increments This is achieved by momentarily p...

Page 29: ...not carried out No Connection No Test This test function ensures that the appliance is plugged into the TnT Titan and that it is switched on If the device is not plugged in and the TnT Titan detects t...

Page 30: ...tags is most aggressive and comes highly recommended for use in the electrical test and tag industry there should be no butterflying once applied Order Information Lightweight ATT Tags 250 Tags Suitab...

Page 31: ...responsibility for any errors or omissions in this document This is partly based on the fact that Electronics Electrical testing and specifications worldwide are constantly changing and that Local St...

Page 32: ...53 4319 E saleswa wavecom com au Wavecom VIC Asian Pacific Offices 18 19 Suite 8 79 83 High Street Kew VIC 2102 P 03 9897 4711 F 08 8243 3501 E service wavecom com au WinPATS Android App Discount Coup...

Reviews: