33
TnP-500
User Manual
Wavecom
Gap/Black Mark Sensor Calibration
Gap/black mark sensor sensitivity should be calibrated in the following circumstances:
1. A brand new printer
2. Change label stock
3. Printer initialization
Please follow the steps below to calibrate the gap/black mark sensor.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes red and flashing. (Any red will do during the 5 flashes).
4. It will calibrate the gap/black mark sensor sensitivity.
• The LED colour will be changed as following order:
1. Amber
2. Red (5 flashes)
3. Amber (5 flashes)
4. Green (5 flashes)
5. Green/amber (5 flashes)
6. Red/amber (5 flashes)
7. Solid green
Note: Sensor calibration can be done by the power on utility.
Note: Please select gap or black mark sensor type prior to calibrate the sensor.
Gap/Black Mark Calibration, Self-test and Dump Mode
While calibrating the gap/black mark sensor, printer will measure the label length, print the internal
configuration (self-test) on label and then enter the dump mode. To calibrate gap or black mark sensor
depends on the sensor setting in the last print job.
Please follow the steps below to calibrate the sensor.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and flashing. (Any amber will do during the 5 flashes)
• The LED colour will be changed as following order.
1. Amber
2. Red (5 flashes)
3. Amber (5 flashes)
4. Green (5 flashes)
5. Green/amber (5 flashes)
6. Red/amber (5 flashes)
7. Solid green
4. The printer will calibrate the sensor and measure the label length and then print the internal settings.
Then it enter Dump Mode.
Note: Sensor calibration can be done by power on utility.
Note: Please select gap or black mark sensor type prior to calibrate the sensor.