background image

Wavecom

User Manual

+ Certificate of Warranty and Product Support Information

TnP-500

Portable Appliance Test and Print Kit

Summary of Contents for TnP-500

Page 1: ...Wavecom User Manual Certificate of Warranty and Product Support Information TnP 500 Portable Appliance Test and Print Kit...

Page 2: ...ntial damages resulting from the breach of any express or implied warranty including damage to property and to the extent permitted by law damages for personal injury The distributors of this product...

Page 3: ...any additional legislation or rulings in different states If in doubt the manufacturer suggests the user contact their responsible authority For maximum safety always ensure that the following advice...

Page 4: ...tion 25 Class 1 Earthed Appliance Construction 25 Class 2 Double Insulated Construction 26 Testing of Electrical Equipment 26 Leakage Test 27 Earth Continuity Test 27 3 Phase Testing 27 Integrated Tes...

Page 5: ...Interface Cable Earth Lead with Alligator Clips 1800mm Black Shockproof Industrial Case IP67 Rated 1 Roll 500 of White Labels 1 Roll of Printing Ribbon WinPATS Software License 12 Month Calibration Ce...

Page 6: ...to recognise at all times whether or not it is safe for work to continue The ability to carry out visual examinations of electrical equipment The ability to distinguish between electrical equipment t...

Page 7: ...standard Insulation and Earth Bond tests it is generally safe to continue If both of the N E red A E green lights are on consult a qualified Electrician This indicates a fault with the Mains Supply D...

Page 8: ...light can indicate a media or general printer fault see Wavecom Thermal Transfer Printer for more information Options Menu During the course of using your TnP 500 you may need to adjust test paramete...

Page 9: ...herwise tap Register Company to set up your Company Account you will be prompted to enable WinPATS permissions this allows you to use the full set of WinPATS features Now fill in your details a valid...

Page 10: ...Ensure that Bluetooth is enabled then select your TnP 500 from the list of available devices ensure you select the correct tester by referring to the serial number Your TnP 500 s serial number is loc...

Page 11: ...inside the storage compartment under the keyboard Once connected open WinPATS on your tablet You should see the Test icon and the Print icon if you connect the printer at the top of the screen change...

Page 12: ...d enter the name of the site Once the details have been typed in press Enter to return Once a site has been entered the F buttons are used to select the site For example to select site 1 F1 would be p...

Page 13: ...g a Site User steps above Ensure that test frequency for the item is set in accordance with the AS NZS 3760 2022 Standard After the item has been visually inspected there is 1 of 3 options that can be...

Page 14: ...ted 7 digits in the barcode and entered 1000 as the barcode the barcode will be 0001000 if leading zeros are enabled To enable leading zeros press F3 To disable press enter The current barcode that wi...

Page 15: ...ction and pass is selected testing can begin Once test has completed the results are displayed To test the item multiple times press F3 this will take you back to the main menu A screen From here you...

Page 16: ...3760 2022 Standard Should it still fail remove it from service Refer to the Technical Information section to change test voltage Note Ensure that the device is isolated from any ground loop Procedure...

Page 17: ...ing especially on surge protected powerboards If unsure always refer to the AS NZS 3760 2022 Standard Should it still fail remove it from service Lead Test Extension Lead Test Menu A F3 Note Extension...

Page 18: ...efore operating ensure the equipment is firmly secured to eliminate the possibility of causing injury or damage This function will power the appliance on and in the case of appliance with movable part...

Page 19: ...nctions section of the manual for more details The factory default setting is 20sec The value for the leakage runtime is also used for the power test Caution Before operating ensure the equipment is f...

Page 20: ...0mA These types of RCD s are mainly used on sites containing medical equipment These types of RCD s must be compliant with the AS3551 standard Please refer to AS3551 for specific guidance Type 2 Has a...

Page 21: ...rent level The TnP 500 displays and maintains the last set trip current value If the user wishes to change the value of the trip current the following steps enable the changes Press F2 from the option...

Page 22: ...pped at 22mA add 2mA to get a value of 24mA trip current To enter the RCD menu from Main Menu B press the F3 button Then to set up a Ramp Test press F2 Before performing an RCD Ramp Test the TnP 500 s...

Page 23: ...l current of a circuit Voltage controls the available electrical power wattage Amperes aka Amps An amp is the unit used to measure electrical current as it flows past a specified point Watts A watt is...

Page 24: ...est 500VDC 250VDC Pass level Greater than 1M Measurement 0 1 to 10 0M Continuity Polarity Test 250VAC check continuity and polarity of leads Displays Pass Fail Leakage Test Leakage Current 0 to 30 0mA...

Page 25: ...s are working properly and are secure and aligned Important If Result is a Fail If any Equipment fails ANY of the above it should be deemed to have FAILED the Visual Test and therefore no other tests...

Page 26: ...servations in testing sensitive electronic equipment using a 500V DC insulation test There is a perceived fear of causing internal damage from over voltage With the TnP 500 these concerns are alleviat...

Page 27: ...eature The Earth Bond test duration can be controlled by the user by pushing the ENTER button during the test This will extent the test time by 30 seconds The TnP 500 will then add 30 seconds to the t...

Page 28: ...s plugged into the TnP 500 and that it is switched on If the device is not plugged in and the TnP 500 detects that no device is present and prompts the user to plug in an appliance to continue the tes...

Page 29: ...ew window 3 Feed Button 4 Label Exit Chute 5 Top Cover Release Lever 6 Power Switch 7 Power Socket 8 USB Interface 9 RS 232C Interface 10 SD Card Slot 11 Ribbon Rewind Hub 12 Print Head 13 Ribbon Rewi...

Page 30: ...maximum open angle 1 Separate the Label Holders by gently pulling them in opposite directions 2 Insert the media between the label holders as shown 3 Using the Media Guide Adjuster Knob adjust the Med...

Page 31: ...angle 4 Push the ribbon into the right axle black then align the notches on the left and insert the ribbon onto the gear blue 2 Insert an empty core between the gear and the axle ensure the notches a...

Page 32: ...lar Button Function Feed labels When the printer is ready press the button to feed one label to the beginning of next label Pause the printing job When the printer is printing press the button to paus...

Page 33: ...rior to calibrate the sensor Gap Black Mark Calibration Self test and Dump Mode While calibrating the gap black mark sensor printer will measure the label length print the internal configuration self...

Page 34: ...wing procedures 1 Turn off the power switch 2 Hold on the button then turn on the power switch 3 Release the button when LED turns green after 5 amber flashes Any green will do during the 5 flashes Th...

Page 35: ...owing guide lists the most common problems that may be encountered when operating this bar code printer If the printer still does not function after all suggested solutions have been invoked please co...

Page 36: ...zation and gap black mark calibration Paper Jam Gap black mark sensor sensitivity is not set properly sensor sensitivity is not enough Calibrate the gap black mark sensor Make sure label size is set p...

Page 37: ...nd a cotton swab or lint free cloth Clean the platen roller when changing a new label roll Tear Bar Peel Bar Use the lint free cloth with 100 ethanol to wipe it As needed Sensor Compressed air or vacu...

Page 38: ...des of ribbons for printing electrical test tags Our standard ribbon WCM Ribbon is recommended for locations where the printed tag is not exposed to harsh outdoor conditions such as offices and factor...

Page 39: ...ifications Model changes may be found on the Wavecom website www wavecom com au At the time of developing this manual all care and consideration for accuracy has been implemented Wavecom accepts no re...

Page 40: ...P 08 9353 1943 F 08 9353 4319 E saleswa wavecom com au Wavecom VIC Mark Kennedy M 0430 299 164 P 03 9897 4711 F 08 8243 3501 E service wavecom com au The TnP 500 is proudly designed and manufactured...