Wavecom Instruments Insulation-Continuity Tester User Manual
Page 7
5. Specifications
INSULATION
● Test Voltage
250Vdc 500Vdc
1000Vdc
+10%-0% +10%-0%
+10%-0%
● Mirror scale
100M
Ω 200MΩ
400M
Ω
● Mid-Scale
1M
Ω
2M
Ω
4M
Ω
● Scale Multiplier
x1/2
x1
x2
● Accuracy
±5%
● Output short-circuit current
±1.3mA
● Regulated output voltage (up to 1mA current)
263.5V 525V
1052V
CONTINUITY
● Low Ω
:
3
Ω / 500Ω
● Test leads / fuse zero Ω adjustment by knob.
● Output short-circuit current
:
205mA
● Accuracy
:
±1.5% of scale length
AC VOLTAGE
● Range
:
0 - 500Vac
● Accuracy
:
±3% of scale length
GENERAL
● Voltage Warning
:
Warning light circuit live illuminate from 90Vdc/70Vac. Buzzer
beep from 24Vac/dc.
● Battery Check
:
Battery Check indicate good batteries from 8Vdc to 13Vdc during
a load test of 205mA.
● Battery OK
:
Battery OK Led illuminate from 8Vdc and is operative while testing.
● Power Source
:
1.5V(AA) x 8
● Dimension
:
175(L) x 85(W) x 75(H)mm
Weight
:
Approx. 650g (battery included)
● Accessories include:
Test leads
Fuse (0.5A/500V 5x20mm)
Carrying case
Instruction manual
Batteries.