1

Box Contents

• 

 One (1) EW-205-24

• 

Accessory bag: 
Cover plate for 4" round outdoor junction box, with two cover plate attachment hole plugs,  

cover plate gasket, cover plate screws & screw covers (4 ea), lens mask, wire nuts (3)

• 

Installation instructions

Contents

DESCRIPTION    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .2

COVERAGE PA

TTERNS    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .2

MOTION SENS

OR PLACEMENT    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Mounting Options   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Mounting and Sensor Positioning Guidelines   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

WIRING AND INSTALLATION    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .5

Senso

r Wire Functions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Connecting to a Power Pack   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Connecting to a DM-105 HID Dimming Module  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Connecti

ng to a DM-115-WP HID Dimming Module   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

TEST

ING AFTER INSTALLATION    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .7

DIAL ADJUSTMENTS    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .7

Adjust Time Delay  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Adjust Light Level  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Making Changes   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

SECURITY OVERRIDE  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9
TROUBLESHOOTING  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9
ORDERING INFORMATION   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .10
WARRA

NTY INFORMATION    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

  

CAUTION

  

READ ALL OF THE INSTALLATION INSTRUCTIONS  

BEFORE INSTALLING THIS PRODUCT .

THIS UNIT MAY BE USED IN APPLICATIONS WITH DEVICES THAT USE HIGH VOLTAGE .  

IT SHOULD ONLY BE INSTALLED BY QUALIFIED PERSONS THAT ARE THOROUGHLY 

FAMILIAR WITH PROPER SAFETY PROCEDURES AND  

ELECTRICAL AND BUILDING CODES FOR THE INSTALLATION LOCATION .

WARNING: TO AVOID FIRE, SHOCK, ELECTROCUTION, OR DEATH—TURN OFF POWER 

AT THE CIRCUIT BREAKER OR FUSE BOX AND TEST TO  

ENSURE POWER IS OFF BEFORE WIRING .

Check Our Web Site For FAQs: www .wattstopper .com

Summary of Contents for EW-205-24

Page 1: ...power packs supply power for up to 11 sensors BZ Series power packs supply power for up to 15 sensors DM 105 HID Bi Level control module supplies power for up to two sensors DM 115 WP Outdoor HID Bi Level control module supplies power for up to two sensors Coverage 270 Time Delay Adjustment 12sec 16min Light Level Adjustment 0 5FC 200FC Operating Temperature 40 to 130 F 40 to 55 C Mountable Locati...

Page 2: ...mming Module 6 TESTING AFTER INSTALLATION 7 DIAL ADJUSTMENTS 7 Adjust Time Delay 7 Adjust Light Level 7 Making Changes 8 SECURITY OVERRIDE 9 TROUBLESHOOTING 9 ORDERING INFORMATION 10 WARRANTY INFORMATION 10 CAUTION READ ALL OF THE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THIS PRODUCT THIS UNIT MAY BE USED IN APPLICATIONS WITH DEVICES THAT USE HIGH VOLTAGE IT SHOULD ONLY BE INSTALLED BY QUALIFIE...

Page 3: ...and is dependent on several factors including weather conditions external light sources mounting height and sensor tilt DESCRIPTION The EW 205 sensor is an outdoor passive infrared PIR motion sensor rated for wet conditions It installs onto a standard round outdoor junction box using the supplied junction box cover plate The EW 205 sensor uses advanced PIR technology and a superior lens design to ...

Page 4: ...er plate mounting as shown in the illustration on the right Horizontally mounted For horizontal mounting such as under eaves rotate the sensor housing as shown in the diagrams below Make sure that the gasket is seated properly Check Our Web Site For FAQs www wattstopper com 3 Remove the two screws at the back of the sensor Rotate the sensor housing 180 Replace and tighten the screws 1 2 3 Attach m...

Page 5: ...ff heltered locations preferred Aim motion sensor downward to limit sensing Mount motion sensor level Do not mount by vents or above lamps Install sensor no higher than 20 from ground Ideal mounting height is 10 to 15 from ground level At least 5 between HID fixture and sensor YES YES YES YES NO NO NO NO NO NO NO Call 800 879 8585 or 972 578 1699 For Technical Support YES ...

Page 6: ...nections to the power pack or DM 105 or DM 115 WP module See the descriptions and wiring diagrams that follow for connections to each specific power source RED 24VDC input to sensor BLACK Common BLUE 24VDC control output from sensor CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE INSTALLING SENSOR SENSOR MUST BE INSTALLED BY QUALIFIED PERSONNEL ONLY 4 round outdoor junction box Cover plate To...

Page 7: ... from sensor to RED wire from the DM 115 WP cable BLACK common wire from sensor to BLACK wire from the DM 115 WP cable BLUE wire from sensor to WHITE wire from the DM 115 WP cable Control Output from Sensor Blue Common Black 24 VDC to Sensor Red DM 105 WP EW 105 24 or EW 205 24 Motion Sensor Ballast Red Black White Connecting to a DM 105 HID Dimming Module Wire the sensor to a WattStopper DM 105 a...

Page 8: ...r s light level adjustment is keeping the sensor inactive Wait until daylight levels have reduced before testing again 5 See Dial Adjustments below for guidelines to adjust the time delay and light level to the desired settings for operation DIAL ADJUSTMENTS Time Delay and Light Level control dials are located on the bottom of the sensor 1 Adjust Time Delay The time delay is the amount of time tha...

Page 9: ...n icon as desired this lowers the light level setting Remember the sensor must detect motion for lights to turn on The lights turn on high later in the evening The lights turn off low sooner in the morning Notes When testing adjustments make sure not to block any of the light that is reaching the sensor or reflect any light into the sensor s lens The sensor requires about 5 seconds for light level...

Page 10: ...age area the sensor should turn lights off low in 12 seconds Reset the time delay to the desired value 3 If the lights do not turn off low have a person qualified to check high voltage connections verify that the sensor and lighting are wired correctly see Wiring and Installation page 5 6 CAUTION Make sure power is turned off at the circuit breaker before checking wiring 4 If the sensor is wired c...

Page 11: ...des cover plate B230E P Power Pack 230VAC 50 60Hz 150mA 20A ballast 13A incandescent B347D P Power Pack 347VAC 60Hz 150mA 15A ballast BZ 50 Power Pack 120 277 VAC 50 60 Hz BZ 150 Power Pack 120 277 VAC 50 60 Hz DM 105 HID Bi Level Control Module DM 115 WP Outdoor HID Bi Level Control Module When ordering add W for Arctic White or G for Architectural Gray to catalog numbers 10 THIRD PARTY ORDERING ...

Page 12: ...2800 De La Cruz Boulevard Santa Clara CA 95050 USA Technical Support 800 879 8585 www wattstopper com 03701r4 09 2014 Please Recycle ...

Reviews: