TROUBLESHOOTING

Lighted switch is OFF, no load response to ON/OFF button press:

•  Make certain that the circuit breaker is on and functioning. 

Lighted switch is ON, no load response to ON/OFF button press:

•  Check the lamp and/or motor switch on the fan mechanism.

Load will not turn OFF automatically:

•  Press ON/OFF button. If the controlled load turns OFF, go to next step.
•  The time delay can be set from 15 seconds to 30 minutes. Check the time 

delay setting for each CH-250 in your multi-way configuration. Ensure that all 

CH-250s have the same time delay setting. 

•  Ensure that there is no movement within the coverage area for all the sensors 

related to the load for the set time delay. Hot air currents and heat radiant 

devices can cause false detection. Make sure the sensor is at least 6 feet (2 

meters) away from devices that are a significant heat source (e.g., heater, 

heater vent, high wattage light bulb).

If load does not respond properly after following troubleshooting, turn OFF 

power to the circuit then check wire connections or call technical support.

WARRANTY INFORMATION

WattStopper warranties its products to be free of defects in materials 

and workmanship for a period of five (5) years. There are no obligations 

or liabilities on the part of WattStopper for consequential damages 

arising out of, or in connection with, the use or performance of this 

product or other indirect damages with respect to loss of property, 

revenue or profit, or cost of removal, installation or reinstallation.

Please 

Recycle

2800 De La Cruz Boulevard, Santa Clara, CA 95050

Technical Support: 800.879.8585 • www.wattstopper.com

COVER PLATES

WattStopper CH wall switches fit behind industry standard decorator style switch 

cover plates.

2800 De La Cruz Boulevard, Santa Clara, CA 95050 

800.879.8585 • www.wattstopper.com 

09563r3 3/2013

Please 

Recycle

Reviews: