STEP 2
Faucet Installation
PARTS LIST FOR FAUCET
ITEM
DESCRIPTION
A
Escutcheon Plate
B
Black Rubber Washer
C
Black Locating Washer (use where A 1/2" hole is avail-
able, reverse when mounting on stainless steel or when
using drilled hole)
D
Lock Washer
E
Nut
F
Insert
G
Plastic Sleeve
H
1/4” Compression Nut
Gather and identify the faucet pieces.
Step A -
Place the escutcheon chrome plate and the black rubber
washer on the threaded stem . (Parts found in faucet parts
bag) .
Step B -
Insert the threaded stem through the hole in sink and let it
rest on the sink top .
Step C -
From the underside of the sink, slide on the location wash-
er, lock washer and brass nut onto the threaded stem .
Check the orientation then tighten brass nut securely .
Step D -
Locate one of the white tubes, then place the compression
nut on the tube first, then the sleeve (small tapered end of
the sleeve must point to the end of tube) and then insert
the plastic insert all the way into the end of the tube .
A
C
D
E
B
F
G
H
Using Quick-Connect Fittings
Cutting
Cut the tube square . It is essential that the outside diameter be free
of score marks and that burrs and sharp edges be removed before
inserting into fitting .
Connecting
Make certain to push the tubing completely into the connector until it
comes into contact with the internal tubing stop . The collet (gripper)
has stainless steel teeth which hold the tube firmly in position while
the O-ring provides a permanent leak proof seal .
Pull on the tube to check that it is secure . It is a good practice to test
the system prior to leaving the site and/or before use .
Disconnecting
To disconnect, ensure the system is depressurized before removing
the tube . Push in collet squarely against the face of the fitting . With
the collet held in this position, the tube can be removed . The fitting
can then be reused .
Step E -
Push the assembled tube into the threaded stem until it
stops . Slide the compression nut and plastic sleeve until
you can thread nut onto the faucet . Use a wrench to se-
curely tighten the compression nut while continuing to push
the tube into the faucet .
Step F -
Connect the other end of the tube into the right side of the
unit, next to the filter labeled “UF Membrane”
NOTICE
DO NOT overtighten nut.
4