5.3 Control a dehumidifier per room
There are 2 ways to detect humidity:
• At controller level using the humidity detection input (See 4.5).
• At the room level if the thermostat embeds a relative humidity sensor.
When humidity is detected, there are 2 ways to trigger dehumidifier:
• A global dehumidifier is triggered by the WFC-03 HCM RF if the feature is activated on the WFC-03 HCM RF.
• A dehumidifier is triggered on the room level where the humidity is detected.
For that last case, you need to pair a BT-WR02 RF receiver on each zone of the controller in order to trigger a dehumidifier.
Device 1: WFC-03 HC RF
Device 2: BT-
WR02 RF
Remarks
By pressing
for 5 seconds, the controller goes in RF pairing menu.
By using
and
select zone 4 (Red blinking led), press
to enter in dehumidifier
Pairing mode.
Choose the zones with
and
.
Zones are defined by paired thermostat channels.
For example if TH1 = Z1, TH2 = Z2+Z3 and TH3 = Z4+Z5+Z6.
Navigation proposes 3 zones to pair a dehumidifier on (Z1), (Z2+Z3) and (Z4+Z5+Z6).
Select/deselect the zone with
(You can select only one zone per dehumidifier)
Cursor is blinking green.
Selected zone is blinking red and green.
Already paired zone is fix green.
(To remove a dehumidifier, select a zone in green, then press simultaneously
on
and
up to get the zone blinking in green).