background image

BT-D03 RF

 

Wireless digital room thermostat
WATTS Vision

®

 System

User Guide

wattswater.eu

Summary of Contents for Vision BT-D03 RF

Page 1: ...BT D03 RF Wireless digital room thermostat WATTS Vision System User Guide wattswater eu ...

Page 2: ... 1 5 Anti freeze mode 5 1 6 OFF mode 6 Functions highlights 9 6 1 Access user parameter menu 9 6 2 Reversible mode 10 6 3 Opened windows detection 10 6 4 Reset 10 6 5 Keyboard locking 10 6 6 PIN code 11 6 7 Other informations 11 6 7 1 Heating and cooling indications 6 7 2 LED indication 6 7 3 Wireless communication functioning 7 User parameter description 12 8 Installer parameter description 15 9 ...

Page 3: ...rry bat teries loose in your pocket or purse Do not remove the battery label Keep batteries away from children If swal lowed consult a physician at once 2012 19 EU WEEE directive Products marked with this symbol cannot be dis posed of as unsorted municipal waste in the European Union For proper recy cling return this product to your local supplier upon the purchase of equiva lent new equipment or ...

Page 4: ...unction Configurable Hysteresis or PWM regu lation Pin Code screws lock for public area EEPROM non volatile memory 2x1 5V AAA batteries LR3 2 parameter menus User and Installer In option External sensor with several possibilities of regulation Floor remote combined 2 BOX CONTENTS WATTS Vision thermostat AAA type Batteries Fixing screws Lock screws Double side tape Back cover and stand for table fi...

Page 5: ...menu Following screens are displaying Other method from parameter menu Note After few seconds the thermostat and the receiver touch screen should exit from the RF init mode this is the normal procedure to confirm a correct pairing To make the installation easier it will be better to have the thermostat near to the receiver or touch screen during the configuration mode 1 Press key to wake up the th...

Page 6: ...r boost mode 6 Locked keyboard 7 Battery level 8 Parameter menu number 9 Parameter menu 10 Indication of heating cooling demand 11 Unit for power consumption 12 Type of measured data sensor used for system regulation Humidity measurement control Internal temperature sensor Ambient temperature sensor Floor temperature sensor External temperature sensor 13 User derogation or adaptive start during Au...

Page 7: ...ccess to menu for selection of mode Press or permits to change navigate in different mode If basic navigation is activated menu 03 navigation menu will be Menu for mode selection Comfort reduced auto stand by boost or antifreeze menus or Automatic selection of current mode Selection of mode Parameter menu No user action after 10 s 2 seconds 5 seconds ...

Page 8: ...Vision touch screen BT CT02 In Auto mode the heating system will follow program according to the current time and the Comfort and Reduced setting temperatures By pressing keys or Boost timer mode is selected it override the temperature set point 1h 5 1 3 Comfort mode In this mode comfort temperature set point will be followed all the time 5 1 4 Reduced ECO mode In this mode reduced temperature set...

Page 9: ...the menu the parameter value is changed with the keys and Pressing again key sets the parameter value Note Thermostat parameters are divid ed into two groups user and installer advanced menu 6 FUNCTIONS HIGHLIGHTS 6 1 Access user parameter menu Comfort reduced auto stand by boost or antifreeze menus Automatic return 10 seconds of keyboard inactivity Mode selection menu Screensaver Navigation menu ...

Page 10: ...emperature set point value is validated 6 3 Opened windows detection Enter user parameter 07 When activated and a detection is run ning the icon will appear and blink on the screen This function is done by measuring and recording the temperature evolution When an opened window is detected the thermostat applies to heating system anti freeze temperature set point User can restart heating system and...

Page 11: ...gos used to indicate than system requires heating is cooling is 6 7 2 LED indication When user modify set point temperature in functioning mode behavior information is displayed with a LED RGB located on the middle of validation key Blue 18 C Azure 20 C Green 22 C Yellow 24 C Red 37 C 6 7 3 Wireless communication functioning When digital thermostat sends an RF frame LCD logo blinks during transmis...

Page 12: ...te a large temperature deviation may indicate an inappropriate installation of the thermostat If the temperature differ ence is too big this could mean your thermostat was not installed properly e g in the right place NOTES If user press simultaneously the keys and sensor calibration is reset No is displayed Default value no for offset of 0 0 C Range values Yes for offset included between 3 0 C an...

Page 13: ...properly e g in the right place NOTES If user press simultaneously the keys and sensor calibration is reset No is displayed Default value no for offset of 0 0 C Range values Yes for offset included between 3 0 C and 3 0 C Open window detection Yes activation of function no no activation More information is in paragraph Opened window detection Default value Yes Values Yes no Authorization or not of...

Page 14: ...s function is available only if digital thermostat is associ ated with a multi zone receiver Displaying client software version Pressing and maintaining key displays software qualifi cation version and debug information Reminder software version is written Vxx xx Professional menu This menu permits to access to installer parameter menus Pressing and maintaining key displays first parameter of inst...

Page 15: ...parameter 20 is FLL Factory setting value no not activated Other values 5 C to FL H High limitation of floor temperature FL H This value is used when parameter 20 is set on floor limit FLL Factory setting value no not activated Other values FL Lo to 40 C Displaying of measured temperature by floor sensor connected to receiver only with specific bidirectional system If Err is displayed thermostat i...

Page 16: ...is menu is not available Factory setting value uf1 Other values uf2 Choice of coating Two choices are possible bP1 for tiling bP2 for wooden floors floating or not if parameter 26 is set to HYs this menu is not available Factory setting value bP1 Other values bP2 Function of pilot wire This option is used to enable the pilot wire functionality if it s used on your installation Factory setting valu...

Page 17: ...no Internal sensor error External sensor Low batteries RF error only when remote is associated to smart home or master product EEPROM clearing All thermostat parameters will be loaded with factory set tings RF wireless communication will be reset too Pressing and maintaining key displays 9 TROUBLESHOOTING SOLUTION Description of thermostat errors displaying Remote errors are Error of temperature m...

Page 18: ...1 C Proportional Band PWM 2 C 10min or Hysteresis 0 2 C to 3 0 C Internal NTC 10kW at 25 C External NTC 10kW at 25 C ß 3950 IP30 Class II 2 Environmental Operating temperature Shipping and storage temperature Setting temperature range Comfort Reduced Holiday Antifreeze Timer Power supply operating life Radio frequency Temperature precision Regulation characteristics Sensing elements Internal Exter...

Page 19: ...pment on the market The WEEE Directive 2012 19 EU aims to reduce the amount of waste electrical and electronic equipment that ends up in landfill The Electromagnetic Compatibility EMC Directive 2014 30 EU ensures that electrical and electronic equipment does not generate or is not affected by electromagnetic disturbance Directive on the restriction of the use of certain hazardous substances in ele...

Page 20: ...tries France 1590 avenue d Orange CS 10101 SORGUES 84275 VEDENE cedex France T 33 4 90 33 28 28 F 33 4 90 33 28 29 39 E mail contact wattswater com http wattswater fr Belgium Watts Benelux Beernemsteenweg 77A 8750 Wingene Belgium T 32 51658708 F 32 51658720 Email benelux wattswater com http wattswater eu Netherlands Watts Water Technologies Benelux Kollergang 14 6961 LZ Eerbeek Netherlands Tel 31 ...