background image

EN

VB25-32-IM-DE-W-UK-05-2023-Rev.1 | Part no. 10025989

9

7 Maintenance

!

 WARNING

Hot water!

Severe scalding possible.

Allow the product (VB25/32) to cool before carrying out any
maintenance, cleaning or work repair.

Do not put hands into hot water when draining the product
(VB25/32).

!

 WARNING

Hot surfaces!

Risk of serious burns.

Do not touch the pipes or components during operation.

Ensure that the product (VB25/32) has cooled down before
carrying out maintenance, cleaning and repair work.

Wear heat-resistant safety gloves if it is necessary to carry out
work on hot components.

 NOTICE

Maintenance of the product (VB25/32) must be carried out only by
trained personnel who have been authorized by the manufacturer.

7.1 Annual maintenance intervals

General visual inspections

1. Check the product (VB25/32) for leaks and retighten sealing

connections or replace seals, as required.

Actions following maintenance work

1. Check that all screw fittings that were unscrewed have been

retightened and retighten if necessary.

2. Remove all tools, materials and other equipment used from

the working area.

3. Fill and vent the system.

7.2 Replacement of wear parts

Please note that the product (VB25/32) contains parts that, for
technical reasons, are subject to wear depending on the intensity
of use, even if the specified care and maintenance have been ob-
served.
This especially applies to mechanical parts and parts that could
come into contact with water and steam, for example, hoses,
seals, valves, etc.
By their nature, defects as the result of wear do not represent a
fault and therefore are not covered by the warranty or the guaran-
tee. Nevertheless, these defects and malfunctions must only be
remedied by trained specialist personnel.
Contact your specialist dealer for this.

Summary of Contents for VB25/32 Series

Page 1: ...Series VB25 32 Boiler manifold for pump groups FlowBox DN 25 32 Installation and operating manual EN WattsWater eu...

Page 2: ...perator is responsible for ensuring compliance with the local laws and regulations e g accident prevention regulations etc Incorrect operation or operating the product Boiler manifold VB25 32 outside...

Page 3: ...ary to the specifications Improper use of the product VB25 32 Modifications to the product VB25 32 that were not agreed with the manufacturer Using replacement or wear parts not approved by the manu f...

Page 4: ...mm 810 x 157 x 80 mm 1110 x 157 x 80 mm 1410 x 157 x 80 mm Total weight excluding packaging 5 6 kg 8 4 kg 12 4 kg 16 5 kg including packaging 5 9 kg 8 8 kg 13 2 kg 17 4 kg Connections to pipe net wor...

Page 5: ...100 1 000 100 1 000 10 000 mbar Pressure loss L h Flow rate 1 outlet open Kvs 15 2 m h 2 outlets open Kvs 20 1 m h VB25 32 2 1 10 100 1 000 100 1 000 10 000 mbar Pressure loss Flow rate L h 2 outlets...

Page 6: ...4 1 outlet open Kvs 14 8 m h 2 outlets open Kvs 21 2 m h 3 outlets open Kvs 24 0 m h 4 outlets open Kvs 24 1 m h 1 10 100 1 000 100 1 000 10 000 VB25 32 5 Pressure loss mbar Flow rate L h 1 oultet op...

Page 7: ...sure to observe the specified installation positions and flow directions of the parts being replaced CAUTION Material damage Opening shut off valves quickly produces pressure surges Always open shut o...

Page 8: ...Part no 10025989 6 3 Installation variants A B A B C D E A B B A C D E 180 180 B A A B E C D E B A B A D C A Return heating circuit B Supply heating circuit C Return boiler circuit D Supply boiler ci...

Page 9: ...product VB25 32 for leaks and retighten sealing connections or replace seals as required Actions following maintenance work 1 Check that all screw fittings that were unscrewed have been retightened a...

Page 10: ...ion a specialist company to do so 2 Sort the assemblies and component parts into recyclable ma terials hazardous substances and operating materials 3 Dispose of the assemblies and components in accord...

Reviews: