Thermostat 560

Compatible With

•  1-stage heating
•  Supports optional floor sensor for radiant floor heating applications

Installation Manual

IOM-T-560

Summary of Contents for tekmar 560

Page 1: ...Thermostat 560 Compatible With 1 stage heating Supports optional floor sensor for radiant floor heating applications Installation Manual IOM T 560 ...

Page 2: ...0 2 7 Application 560 3 8 Application 560 4 9 Sequence of Operation 10 Heating Operation 10 User Interface 11 User Settings 12 Away 12 Schedule 12 Display 13 Time 14 Installer Settings 15 Setup 15 Setup Toolbox 15 Setup Temp 16 Setup Sensors 17 Setup Alerts 17 Setup Relays 17 Error Messages 18 Technical Data 19 Limited Warranty and Product Return Procedure 20 Table of Contents ...

Page 3: ...minor or mod erate injury This symbol identifies practices actions or failure to act which could result in property damage or damage to the equipment Read Manual and all product labels BEFORE using the equipment Do not use unless you know the safe and proper operation of this equipment Keep this Manual available for easy access by all users Replacement Manuals are available at tekmarControls com I...

Page 4: ... than 90 Non condensing environment No exposure to extreme temperatures beyond 32 122 F 0 50 C No draft direct sun or other cause for inaccurate temperature readings Away from equipment appliances or other sources of electrical interference Easy access for wiring viewing and adjusting the display screen Approximately 5 feet 1 5 m off the finished floor The maximum length of wire is 500 feet 150 m ...

Page 5: ...the circuit being worked on turned off Please be aware local codes may require this thermostat to be installed or con nected by an electrician Thermostat Front Thermostat Base Stud Switch Box 3 1 4 83 mm While holding the base section in one hand pull the lower half of the display front towards you to pivot it away from the base Wall Stud Thermostat Front Thermostat Base Removing The Thermostat Ba...

Page 6: ...ay C R AWAY W Legend B1 Boiler BP Boiler Pump PS System Pump T1 Thermostat 560 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V B1 BP PS V1 T1 ZVC1 ZVC1 The Thermostat 560 operates a radiant floor heating system The thermostat uses the built in air tem perature sensor Mechanical Electrical Application 560 1 ...

Page 7: ...B1 Boiler BP Boiler Pump PS System Pump T1 Thermostat 560 S1 Floor Sensor 079 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V ZVC1 B1 BP PS V1 S1 T1 ZVC1 The Thermostat 560 operates a radiant floor heating system based upon the floor temperature sen sor The built in air sensor is disabled Mechanical Electrical Application 560 2 ...

Page 8: ...or can be either built in and or external B1 BP PS V1 S1 S2 T1 ZVC1 Legend ZVC1 Thermostat 560 C R RH1 W1 AWAY S1 S2 SEN COM Zone Valve Control or Switching Relay C R AWAY W B1 Boiler BP Boiler Pump PS System Pump T1 Thermostat 560 S1 Floor Sensor 079 S2 Optional Indoor Sensor 084 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V Mechanical Electrical Application 560 3 ...

Page 9: ... be either built in and or external B1 BP PS V1 S1 T1 ZVC1 ZVC1 Thermostat 560 C R RH1 W1 AWAY S1 S2 SEN COM Zone Valve Control or Switching Relay C R AWAY W Legend B1 Boiler BP Boiler Pump PS System Pump T1 Thermostat 560 S1 Optional Indoor Sensor 084 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V Mechanical Electrical Application 560 4 ...

Page 10: ...ttings are available For a combination of air and floor temperature control leave the internal air sensor on in the setup menu A floor minimum can be used to prevent a fast drop in temperature caused by receding solar exposure This operation is recommended for areas heated by afternoon sun through large windows When the sun sets it can take a long time for the floors to get warm again This may cau...

Page 11: ...ule applies the new temperature to the current schedule event Go to settings Swipe to view Outdoor temperature Floor temperature Heat To setting Go to schedule After 60 seconds of inactivity the thermostat home screen displays only the time and the temperature Save Cancel Mode Off Heat Temperature Adjustment Hold Until 5 00 PM Save to Schedule 70 Heat To MENU SELECTION AWAY SCHEDULE DISPLAY TIME S...

Page 12: ...n Wake 6 00 AM 70 Leave 8 00 AM 65 Return 6 00 PM 70 Sleep 10 00 PM 65 Schedule Mon Tue Wed Thu Fri Info Set heating temperature Select skip if you don t want a temperature change Set schedule start time On Skip Wake Schedule Setup Mon Tue Wed Thu Fri 6 00 AM Heat to 70 Operates normally Operates using the Away temperature selected in the Setup menu Use the Away setting to save energy when the bui...

Page 13: ... 30 to 100 100 BRIGHTNESS INACTIVE Select the brightness when not in use Off 30 to 100 50 BACKGROUND Select the background color Light Blue Night Latte Espresso Blue LANGUAGE Select the language English Español Français English SCREEN CLEAN Locks screen for 10 seconds to allow cleaning N A N A INACTIVE TIME DISPLAY Select if the time is visible when the display is inactive Off or On On INACTIVE OU...

Page 14: ... time format 12 or 24 hour 12 hour DAYLIGHT SAVING TIME Select the brightness when not in use Off On On The time and date is manually set by highlighting a field and then using the or buttons Choose from the time options listed below TIME DATE 1 30 PM Aug 25 2016 OPTIONS Time ...

Page 15: ... Select between user and installer access levels User access level restricts access in the Setup Menu User Installer Installer STATUS The current status of warm weather shut down cold weather shut down and each of the relays WWSD W1 N A SOFTWARE VERSION Display the software version J1302 1 0 0 N A LOAD DEFAULTS All settings are returned to factory defaults Yes No No CALIBRATE TOUCHSCREEN Recalibra...

Page 16: ...oor temperature while in the sleep schedule Applies when there is both a floor and an air sensor Off 40 to 95 F Off 4 5 to 35 0 C Off FLOOR MIN AWAY Select the floor temperature while in away Applies when there is both a floor and an air sensor Off 40 to 95 F Off 4 5 to 35 0 C Off Screen Page 2 FLOOR MAX Select the maximum floor temperature This protects the floor covering from over heating Applie...

Page 17: ...connected to S2 and Com wiring terminals Off Room Floor Outdoor Off INTERNAL ROOM SENSOR Select if the internal room temperature sensor is on or off Only available when Sensor 1 or 2 is set to read a room or floor sen sor Off On On ROOM OFFSET Select if the internal room temperature sensor is on or off Only available when Sensor 1 or 2 is set to read a room or floor sen sor Off 5 to 5 F 3 0 to 3 0...

Page 18: ...cording to the sensor installation manual It may be necessary to replace the auxiliary sensor Once the error has been corrected the error message automatically clears SENSOR 2 FAULT Due to an open or short circuit the thermostat is unable to read the sensor wired to S2 and Com The thermostat stops normal operation if sensor 2 is the only active room or floor sensor or if a floor maximum temperatur...

Page 19: ...s 4 5 8 H x 3 W x 15 16 D 118 x 76 x 24 mm Enclosure White PVC plastic NEMA Type 1 Approvals Meets Class B ICES FCC Part 15 Ambient conditions Indoor use only 32 to 122 F 0 to 50 C RH 90 non condensing Power supply 15 to 30 V ac dc 2 VA standby Class 2 Relays 30V ac dc 2 A Class 2 circuits Sensor NTC thermistor 10 kΩ 77 F 25 C 0 2 C ß 3892 Included None Optional tekmar type 070 072 073 076 077 079...

Page 20: ...t the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation Purchaser shall indemnify and hold tekmar harmless from and against any and all claims liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to i...