Combustion Air (C.A.) Damper (Terminals 17, 18)
A C .A . damper requiring up to 230 V (ac) 5 A, 1/3 hp can be switched through terminals
17 and 18 .
For 24 V(ac) actuators:
• Connect the power supply red (R) to terminal 17 .
• Connect a wire from terminal 18 to the R on the combustion air damper .
• Connect the C on the combustion air damper to the power source common C .
FCC ID: 2AHQR-11500A
Contains FCC ID:
2AC7Z-ESP32WROOM32E
QOQMGM12P0
Contains IC ID:
21098-ESPWROOM32E
5123A-MGM12P0
CAN ICES-3 (A)/NMB-3(A)
Class 2 Circuits
Input Power:
115 V (ac) ±10%, 60 Hz, 4 W
Relays:
230 V (ac), 5 A, 1/3 hp
Calls:
24 V (ac) or Short
Operating Temperature:
32°F to 122°F (0°C to 50°C)
Use Copper Conductors Only
Wi-Fi: 802.11b/g/n, 2.4GHz
12
10/100
Ethernet
14
13
Boiler
1
Enable
16
15
Boiler 2
Enable
18
17
Comb
Air Relay
20
19
Power
N
DANGER
DANGER
To Reduce the Risk of Electric
Shock - Do not connect to a
circuit operating at more than
150 volts to ground.
Pour réduire les risques
d'électrocution choc - ne pas
raccorder à un circuit
fonctionnant à plus de 150 V à
la terre.
L
5
4
Outdoor
7
6
Cond
Sensor
9
8
Aux
Sensor
11
10
DHW
2 3
1
Ref In Gnd
Pressure Sens
Call
+
Sensor
H2065A
Smart Steam Control 289
For product literature:
Pour la documentation
du produit:
tekmarControls.com
tektra 1150-02
Designed and assembled
in Canada
T T
T T
C
G
R
R C
G
For 120 V(ac) actuators:
• Connect the power Line (L) to terminal 17 .
• Connect a wire from terminal 18 to the Line on the combustion air damper .
• Connect the neutral (N) on the combustion air damper to the power source common C .
FCC ID: 2AHQR-11500A
Contains FCC ID:
2AC7Z-ESP32WROOM32E
QOQMGM12P0
Contains IC ID:
21098-ESPWROOM32E
5123A-MGM12P0
CAN ICES-3 (A)/NMB-3(A)
Class 2 Circuits
Input Power:
115 V (ac) ±10%, 60 Hz, 4 W
Relays:
230 V (ac), 5 A, 1/3 hp
Calls:
24 V (ac) or Short
Operating Temperature:
32°F to 122°F (0°C to 50°C)
Use Copper Conductors Only
Wi-Fi: 802.11b/g/n, 2.4GHz
12
10/100
Ethernet
14
13
Boiler
1
Enable
16
15
Boiler 2
Enable
18
17
Comb
Air Relay
20
19
Power
N
DANGER
DANGER
To Reduce the Risk of Electric
Shock - Do not connect to a
circuit operating at more than
150 volts to ground.
Pour réduire les risques
d'électrocution choc - ne pas
raccorder à un circuit
fonctionnant à plus de 150 V à
la terre.
L
5
4
Outdoor
7
6
Cond
Sensor
9
8
Aux
Sensor
11
10
DHW
2 3
1
Ref In Gnd
Pressure Sens
Call
+
Sensor
H2065A
Smart Steam Control 289
For product literature:
Pour la documentation
du produit:
tekmarControls.com
tektra 1150-02
Designed and assembled
in Canada
T T
T T
N
G
L
L N
G
Input Power (Terminals 19, 20
Provide a 15 Amp circuit for the input power .
• Connect the 115 V (ac) line wire (L) to terminal 19 .
• Connect the neutral wire (N) to terminal 20 .
FCC ID: 2AHQR-11500A
Contains FCC ID:
2AC7Z-ESP32WROOM32E
QOQMGM12P0
Contains IC ID:
21098-ESPWROOM32E
5123A-MGM12P0
CAN ICES-3 (A)/NMB-3(A)
Class 2 Circuits
Input Power:
115 V (ac) ±10%, 60 Hz, 4 W
Relays:
230 V (ac), 5 A, 1/3 hp
Calls:
24 V (ac) or Short
Operating Temperature:
32°F to 122°F (0°C to 50°C)
Use Copper Conductors Only
Wi-Fi: 802.11b/g/n, 2.4GHz
12
10/100
Ethernet
14
13
Boiler
1
Enable
16
15
Boiler 2
Enable
18
17
Comb
Air Relay
20
19
Power
N
DANGER
DANGER
To Reduce the Risk of Electric
Shock - Do not connect to a
circuit operating at more than
150 volts to ground.
Pour réduire les risques
d'électrocution choc - ne pas
raccorder à un circuit
fonctionnant à plus de 150 V à
la terre.
L
5
4
Outdoor
7
6
Cond
Sensor
9
8
Aux
Sensor
11
10
DHW
2 3
1
Ref In Gnd
Pressure Sens
Call
+
Sensor
H2065A
Smart Steam Control 289
For product literature:
Pour la documentation
du produit:
tekmarControls.com
tektra 1150-02
Designed and assembled
in Canada
N
G
L
T T
T T