background image

4

Specifications

Feed Water Parameters 

       

Do not use this system on water that is microbiologically 

unsafe or of unknown quality without adequate disinfection 

before or after the system !

Minimum inlet pressure: 30 psig
Maximum operating pressure: 125 psig
Minimum water temperature: 34°F (1°C)
Maximum water temperature: 110°F (43°C)

Power

Voltage: 120VAC
Frequency: 60Hz
Power consumption: 7 Watts Maximum

Installation 

Location: Indoors (Protect from direct sunlight)
Minimum ambient temperature: 34°F (1°C)
Maximum ambient temperature: 122°F (50°C)

!

moDeL no.

VaLVe

mIneraL tank 

sIze

meDIa cubIc 

Foot

GraVeL  

(Lbs)

peak serVIce 

FLow (Gpm)*

pressure Drop

back wash  

(Gpm)

FLoor space 

L X w X h

PWSYS-WH-CAL-1CUFT

Time Clock

9" X 48"

1

10

5

<15

7

16" X 10" X 55"

PWSYS-WH-CAL-1.5CUFT

Time Clock

10" X 54"

1.5

10

7

<15

7

16" X 11" X 62"

PWSYS-WH-CAL-2CUFT

Time Clock

12" X 52"

2

30

10

<15

10

17" X 13" X 60"

PWSYS-WH-CAL-3CUFT

Time Clock

13" X 65"

3

40

15

<15

15

18" X 14" X 74"

*note:

 Peak service flow rate is for intermittent use only and is not to be interpreted as continuous service flow rate capability. These systems are designed to treat the domestic water used in a 

single family dwelling. For irrigation water treatment or higher volume applications please contact your Watts representative.

moDeL no.

VaLVe

mIneraL tank 

sIze

meDIa cubIc 

Foot

GraVeL  

(Lbs)

serVIce FLow* 

(Gpm)

pressure Drop 

(psI)

back wash 

(Gpm)

FLoor space 

LXwXh

PWSYS-WH-MICROZ-1CUFT

Time Clock

9" X 48"

1

10

9

15

7

16" X 10" X 55"

PWSYS-WH-MICROZ-1.5CUFT

Time Clock

10" X 54"

1.5

10

10

15

7

16" X 11" X 62"

PWSYS-WH-MICROZ-2CUFT

Time Clock

12" X 52"

2

30

10

15

10

17" X 13" X 60"

PWSYS-WH-MICROZ-3CUFT

Time Clock

13" X 65"

3

40

15

15

15

18" X 14" X 74"

moDeL no.

VaLVe

mIneraL tank 

sIze

meDIa cubIc 

Foot

GraVeL (Lbs)

serVIce FLow* 

(Gpm)

pressure Drop 

(psI)

back wash 

(Gpm)

FLoor space 

LXwXh

PWSYS-WH-GAC-1CUFT

Time Clock

  9" X 48"

1

10

3.7

<15

4

16" X 10" X 55"

PWSYS-WH-GAC-1.5CUFT

Time Clock

10" X 54"

1.5

10

5.5

<15

5

16" X 11" X 62"

PWSYS-WH-GAC-2CUFT

Time Clock

12" X 52"

2

30

7.4

<15

7

17" X 13" X 60"

PWSYS-WH-GAC-3CUFT

Time Clock

13" X 65"

3

40

11.1

<15

9

18" X 14" X 74"

PWSYS-WH-GAC-4CUFT

Time Clock

16" X 65"

4

60

14.8

<15

15

20" X 17" X 74"

Drain Flow Rates - 

The drain system these filters 

are plumbed to must be able to accept the listed drain 
volumes for a period of 27 minutes.

Micro Z™ Filters

  9" X 48", 1 cubic ft. 

7 gpm

  10" X 54", 1.5 cubic ft. 

7 gpm

  12" X 52", 2 cubic ft. 

10 gpm

  13" X 65", 3 cubic ft. 

15 gpm

Carbon Filters:

  9" X 48", 1 cubic ft. 

4 gpm

  10" X 54", 1.5 cubic ft. 

5 gpm

  12" X 52", 2 cubic ft. 

7 gpm

  13" X 65", 3 cubic ft. 

9 gpm

  16" X 65", 4 cubic ft. 

15 gpm

Calcite Filters:

  9" X 48", 1 cubic ft. 

7 gpm

  10" X 54", 1.5 cubic ft. 

7 gpm

  12" X 52", 2 cubic ft. 

10 gpm

  13" X 65", 3 cubic ft. 

15 gpm

Summary of Contents for PWSYS-WH-MICROZ

Page 1: ...ection before or after the system Local building or plumbing codes may require modifications to the information provided You are required to consult the local building and plumbing codes prior to inst...

Page 2: ...e filter see the Installation Considerations section of this manual Do not attempt to treat water over 110 F 43 C with the system Always connect the system to the main water sup ply pipe before the wa...

Page 3: ...3 Filter Anatomy 1 2 3 4 5 6 7 Item Description 1 Valve 2 Bypass 3 Tank 4 Distributor 5 Filter Media Calcite Carbon or Micro Z 6 Faceplate Controls 7 Gravel Underbed...

Page 4: ...tact your Watts representative MODEL NO Valve Mineral Tank Size Media Cubic Foot Gravel Lbs Service Flow GPM Pressure Drop PSI Back Wash GPM Floor Space LXWXH PWSYS WH MICROZ 1CUFT Time Clock 9 X 48 1...

Page 5: ...rings on the bottom of the control valve dis tributor pilot O ring and top of tank O ring Use non petroleum based silicone lubricant only 7 Place the control valve on top of the tank When doing this...

Page 6: ...ape on all external pipe threads Do not use pipe joint compound CAUTION Support inlet and outlet plumbing in some manner use pipe hangers to keep the weight off of the valve fittings 7 Place bypass va...

Page 7: ...flowing through the system and sediment is being removed from your water if it s a Micro Z filter If it s a carbon filter it removes chlorine tastes odors and organics from your water If your system c...

Page 8: ...remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED...